DXS-1210 Series Smart Managed Switch CLI Reference Guide
326
Both the surveillance vlan command in Global Configuration Mode and the surveillance vlan
enable command in Interface Configuration Mode need to be enabled for a port to start the
surveillance VLAN function.
When surveillance VLAN is enabled for a port, the port will be automatically learned as surveillance
VLAN untagged member, the received untagged surveillance packets will be forwarded to
surveillance VLAN. The received packets are determined as surveillance packets if the source MAC
addresses of packets comply with the organizationally unique identifier (OUI) addresses configured by
the surveillance vlan mac-address command.
Example
This example shows how to enable surveillance VLAN function on physical port eth1/0/1.
Switch# configure terminal
Switch(config)#interface eth 1/0/1
Switch(config-if)#surveillance vlan enable
Switch(config-if)#
41-4
surveillance vlan mac-address
This command is used to add the user-defined surveillance device OUI. Use the no form of this
command to delete the user-defined surveillance device OUI.
surveillance vlan mac-address MAC-ADDRESS MASK [component-type {vms | vms-client |
video-encoder | network-storage | other} description TEXT]
no surveillance vlan mac-address MAC-ADDRESS MASK
Parameters
MAC-ADDRESS
Specifies the OUI MAC address.
MASK
Specifies the OUI MAC address matching bitmask.
component-type
(Optional) Specifies surveillance components that could be auto-
detected by surveillance VLAN.
vms
(Optional) Specifies thesurveillance components type as Video
Management Server (VMS).
vms-client
(Optional) Specifies the surveillance components type as VMS client.
video-encoder
(Optional) Specifies the surveillance components type as Video
Encoder.
network-storage
(Optional) Specifies the surveillance components type as Network
Storage.
other
(Optional) Specifies the surveillance components type as other IP
Surveillance Devices.
description TEXT
(Optional) Specifies the description for the user-defined OUI with a
maximum of 32 characters.
Default
OUI Address
Mask
Component Type
Description
28-10-7B-00-00-00
FF-FF-FF-E0-00-00
D-Link Device
IP Surveillance Device
28-10-7B-20-00-00
FF-FF-FF-F0-00-00
D-Link Device
IP Surveillance Device
B0-C5-54-00-00-00
FF-FF-FF-80-00-00
D-Link Device
IP Surveillance Device
F0-7D-68-00-00-00
FF-FF-FF-F0-00-00
D-Link Device
IP Surveillance Device