xStack Storage User’s Guide
89
–
Right-click and click
Set Spare Count
.
Either step displays the Set Spare Count dialog box, with the current setting shown (see
Figure 5-39).
Figure 5-39. Set Spare Count Dialog Box
Enter a value that corresponds to the number of drives and click
OK
.
5.4.12
Using the Down Drive Feature
The xStack Storage Array provides a Down Drive feature that allows a drive to be removed from
the system in an orderly way. Using this feature, you can, for example, replace a smaller drive
with a larger drive, or replace a drive for which S.M.A.R.T. has projected a failure. The xStack
Storage Array can perform up to five concurrent Down Drive operations at one time.
The Down Drive operation requires all space used on the drive to be relocated onto different
drives. The Down Drive feature handles this requirement by performing a reconfigure task on
every volume that uses space on the drive. This operation is conducted for any type of volume,
including redundant and non-redundant organizations.
When all space has been moved off the drive, the drive is moved to the
Unusable Pool
and can
be removed from the system.
5.4.12.1
Initiating the Down Drive Operation
To use the Down Drive feature, right-click the drive you want to remove and click
Down Drive
.
The Down Drive task appears in the task pane of the xStack Storage Array management console.
One reconfigure task is created automatically for each volume that used space on the selected
drive. The reconfigure tasks are issued one at a time. The progress of the Reconfigure and Down
Drive tasks can be monitored on the task pane.
5.4.12.2
Suspending and Resuming the Down Drive Operation
To suspend the Down Drive operation:
1.
Select the Down Drive task.
2.
Right-click and select the
Suspend
option.
To resume the Down Drive operation, right click and select the
Resume
option.
Содержание DSN-3200 - xStack Storage Area Network Array Hard Drive
Страница 10: ...x Contents ...
Страница 20: ...20 Chapter 2 Identifying Hardware Components Figure 2 6 Press Lever Inwards Until it Locks ...
Страница 36: ......
Страница 44: ...44 Chapter 4 Starting the xStack Storage Array for the First Time ...
Страница 48: ...48 Chapter 5 Configuring the xStack Storage Array Figure 5 3 xStack Storage Management Console Main Screen ...
Страница 103: ...xStack Storage User s Guide 103 ...
Страница 117: ...xStack Storage User s Guide 117 Figure 6 12 Viewing SMART Attributes ...
Страница 160: ...160 Appendix D Replacing and Upgrading FRUs ...
Страница 164: ...164 Appendix F Hardware Enclosures ...
Страница 168: ...168 Appendix G Acronyms and Abbreviations ...