146
Appendix C Performing Advanced Diagnostics
Appendix D Replacing and Upgrading FRUs
This appendix describes how to replace or upgrade the Field Replaceable Units (FRUs) in your
xStack Storage Array. FRUs that can be replaced or upgraded include:
Battery Pack
System and buffer memory
SATA drives
Fans
Uninterruptible power supplies
D.1 Installing the Battery Pack
The xStack Storage Array accommodates a 4-cell or 6-cell shrink-wrapped battery pack.
Because write-back caching is always enabled, we recommend you have a battery to back up
the buffer cache contents.
To install a battery in your xStack Storage SAN Array, follow these steps:
1.
Hold the battery as shown to align the fastener pad. Make sure the battery cable and
connector is located nearest to the battery socket J35 on the controller (see Figure D-1 ).
Figure D-1 Aligning the Battery
Содержание DSN-3200 - xStack Storage Area Network Array Hard Drive
Страница 10: ...x Contents ...
Страница 20: ...20 Chapter 2 Identifying Hardware Components Figure 2 6 Press Lever Inwards Until it Locks ...
Страница 36: ......
Страница 44: ...44 Chapter 4 Starting the xStack Storage Array for the First Time ...
Страница 48: ...48 Chapter 5 Configuring the xStack Storage Array Figure 5 3 xStack Storage Management Console Main Screen ...
Страница 103: ...xStack Storage User s Guide 103 ...
Страница 117: ...xStack Storage User s Guide 117 Figure 6 12 Viewing SMART Attributes ...
Страница 160: ...160 Appendix D Replacing and Upgrading FRUs ...
Страница 164: ...164 Appendix F Hardware Enclosures ...
Страница 168: ...168 Appendix G Acronyms and Abbreviations ...