211
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid
for this configuration.
This command configures the RX power thresholds on the specified port. This value will be stored
both in the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then
written into the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is
just stored in the system and the displayed value will be the user-configured threshold. If there is no
user-configured threshold, the displayed value will always reflect the factory preset value defined by
the vendor.
The
no
form of this command has the effect to clear the configured threshold stored in system. It does
not change the threshold stored in the SFP/SFP+ transceivers. Use the
no
form of this command to
prevent threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the temperature high alarm threshold as 127.994 on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring temperature eth3/0/1 high alarm 127.994
WARNING: A closest value 127.992 is chosen according to the transceiver-monitoring
precision definition.
Switch(config)#
22-8
transceiver-monitoring tx-power
This command is used to configure the output power threshold for the specified port. Use the
no
form
of this command to remove the configuration.
transceiver-monitoring tx-power INTERFACE-ID {high | low} {alarm | warning} {mwatt
VALUE | dbm VALUE}
no transceiver-monitoring tx-power INTERFACE-ID {high | low} {alarm | warning}
Parameters
high
Specifies the interface to modify.
low
Specifies that when the operating parameter rises above this high
threshold value, it indicates an abnormal status.
alarm
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
warning
Specifies to configure the high and low warning threshold
conditions.
mwatt VALUE
Specifies the power threshold value in milliwatts. This value must be
between 0 and 6.5535.
dbm VALUE
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.
Default
None.
Содержание DGS-510
Страница 1: ...1 ...
Страница 287: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 284 ...
Страница 321: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 318 ...
Страница 493: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 490 ...
Страница 733: ...DGS 1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide 730 ...