xStack® DGS-3620 Series Managed Switch Web UI Reference Guide
207
Figure 5-73 MLD Interface Settings –Edit window
The fields that can be configured are described below:
Parameter
Description
Query Interval (1-
31744)
Enter a value between 1 and 31744 seconds, with a default of 125 seconds. This
specifies the interval between sending MLD queries.
State
Use the drop-down menu to enable or disable MLD for the IP interface. The default is
Disabled.
Version
Use the drop-down menu to select the MLD version that will decide the interface to
send and process which version packets.
Max Response Time
(1-25)
Enter a value between 1 and 25 to specify the maximum amount of time allowed
before sending an MLD response report. The default time is 10 seconds.
Robustness Variable
(2-7)
A tuning variable to allow for subnetworks that are expected to lose a large number of
packets. A value between 2 and 7 can be entered, with larger values being specified
for subnetworks that are expected to lose larger numbers of packets. The default
setting is 2.
Last Member Query
Interval (1-25)
Enter a value between 1 and 25 to specify the maximum amount of time between
group-specific query messages, including those sent in response to leave group
messages. The default is 1 second.
Click the
<<Back
button to return to the previous window.
Click the
Apply
button to accept the changes made.
MLD Group Table
The window is used to display the MLD static groups on the Switch.
To view the following window, click
L3 Features > IP Multicast Routing Protocol > MLD > MLD Group Table
, as
shown below:
Figure 5-74 MLD Group Table window
Содержание DGS-3620-28PC-SI
Страница 1: ......