DGS-3100 Series Gigabit Stackable Managed Switch User Manual
222
ID SEVERITY
CATEGORY
MESSAGE DESCRIPTION
SYSLG8.97.18 Error
System
Memory for notifying
applicaton %(1)s could
not be allocated.
Memory for notifying the
specified application could
not be allocated.
SYSLG1.0.55
Information
al
Up/Download
File %(1)s has been Auto
Updated
The specified file has been
Auto Updated.
SYSLG1.0.56
Information
al Up/Download
Auto Update Completed;
rebooting the switch
Auto Update is completed.
The switch is being;
rebooted.
SYSLG1.0.59
Information
al Up/Download
Active image successfully
changed to image %(1)d
Active image is
successfully changed to the
specified image.
SYSLG1.2.4
Information
al
entity configuration
change trap.
SYSLG1.3.0
Information
al
Interface
Pse Port %(1)s delivering
power to the PD.@
The specified PSE port is
delivering power to the PD.
SYSLG1.3.1
Information
al System
PSE power usage %(1)d
in unit %(2)d is above the
threshold.@
The PSE power used by the
specified unit is above the
threshold.
SYSLG1.3.2
Information
al
System
PSE power usage %(1)d
in unit %(2)d is below the
threshold.@
The PSE power used by the
specified unit is below the
threshold.
SYSLG1.5.23
Information
al
Interface
Unit %(1)d was shutdown
- JUMBO frames not
supported.
The specified unit is
shutdown because Jumbo
frames are not supported.
SYSLG1.5.24
Information
al
Stack
Master switchover: unit
%(1)d is now master.
The specified unit is now
the Master unit.
SYSLG1.5.25
Information
al
Stack
Backup master unit %(1)d
was removed from the
stack.
The specified backup
master is removed from the
stack.
SYSLG1.5.26
Information
al
Stack
Unit %(1)d was removed
from the stack.
The specified unit is
removed from the stack.
SYSLG1.5.28
Information
al
IP
Ipc connection with unit
%(1)d failed.
The IPC connection with
the specified unit has failed.
SYSLG1.5.29
Information
al
Configuration changed:
%(1)s
SYSLG1.5.30
Information
al
Stack
Stack cable %(1)s : link
%(2)s on unit-%(3)d
The specified stacking cable
is connected to the specified
unit.
SYSLG1.6.11
Information
al
PS# %(1)d status changed
- %(2)s.
The system uses two power
supply sources: #1 and #2.
The system can operate
with one or both power
supply units. The power
supply has changed.
SYSLG1.6.8
Information
al
System
FAN# %(1)d status
changed - %(2)s.
The specified fan status has
changed.
SYSLG4.10.13
Information
al
Add dynamic MAC
%(1)m - Vlan %(2)d
failed, %(3)d mac failed to
be inserted from the last