4 Configuration
DGS-1210 series Metro Ethernet Managed Switch User Manual
1
1
3
3
5
5
ACL rule to limit traffic. The step of bandwidth is 64kbps. Due to limited metering rules, not all ACL rules can
associate with a metering rule.
Figure 4.210 - ACL > ACL Flow Meter
Profile ID:
The pre-configured Profile ID for which to configure the Flow Metering parameter.
Access ID (1-128):
The pre-configured Access ID for which to configure the Flow Metering parameters.
Enter the appropriate information and click
Find
the entries will be displayed on the lower half of the table.
To edit and entry click the corresponding
Modify
button, to delete an entry click the corresponding
Delete
button, to add a new entry click the
Add
button which will display the following window for the user to
configure.
Figure 4.211 - ACL > Add ACL Flow Meter
Profile ID (1-6):
Specify the profile ID.
Access ID (1-128):
Specify the Access ID that will be used to configure the Flow Metering parameters, enter
a value between 1 and 128.
Mode:
To be used the corresponding information.
-
Rate: Specify the committed information Rate of the packet. The range is from 64 to 1024000
kbyte.
Содержание DGS-1210 Series
Страница 159: ...140 ...