 1.

 All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2. 

Power supply from mains

The mains voltage is sufficiently high to involve a risk of electrocution; install and 

a. 

connect this product before plugging it in.
Before powering up, make sure that all the connections have been made correctly and 

b. 

the voltage of your mains corresponds to the voltage shown on the rating plate on the 
unit, if not, please contact your RCF dealer.
The metallic parts of the unit are earthed through the power cable. An apparatus with 

c. 

CLASS I construction shall be connected to a mains socket outlet with a protective 
earthing connection.
Protect the power cable from damage; make sure it is positioned in a way that it 

d. 

cannot be stepped on or crushed by objects.
To prevent the risk of electric shock, never open this product: there are no parts inside 

e. 

that the user needs to access.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit.
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid, 
such as vases, shall be placed on this apparatus. No naked sources (such as lighted candles) 
should be placed on this apparatus.

4.

 Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.
Contact your authorized service centre or qualified personnel should any of the following 
occur:

The product does not function (or functions in an anomalous way).

 -

The power cable has been damaged.

 -

Objects or liquids have got in the unit.

 -

The product has been subject to a heavy impact.

 -

5.

 If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately 

and disconnect the power cable.

7.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 
this product by using elements that are unsuitable or not specific for this purpose. Also 
check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets 
not supplied by RCF etc.), which must guarantee the security of the system / installation 
over time, also considering, for example, the mechanical vibrations normally generated by 
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless 
this possibility is specified in the user manual.

8. RCF S.p.A. strongly recommends this product is only installed by professional 
qualified installers (or specialised firms) who can ensure correct installation 
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations 
regarding electrical systems.

9.

 Supports and trolleys

The  equipment  should  be  only  used  on  trolleys  or  supports,  where  necessary,  that  are 
recommended by the manufacturer. The equipment / support / trolley assembly must be 

SAFETY

PRECAUTIONS

IMPORTANT

Содержание HD 12-A

Страница 1: ...OWNER MANUAL HD 10 A HD 12 A PROFESSIONAL ACTIVE SPEAKER SYSTEMS...

Страница 2: ...2 ENGLISH ENGLISH ITALIANO FRAN AIS DEUTSCH LANGUAGE 3 8 13 17...

Страница 3: ...ur The product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this prod...

Страница 4: ...T NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Lou...

Страница 5: ...lass D power amplifiers technology packs huge performance operating with high efficiency into a lightweight solution D LINE amplifiers deliver ultra fast attack realistic transient response and impres...

Страница 6: ...green led is ON when the speaker is connected to the main power supply and the ON OFF is in ON position MALE XLR SIGNAL OUTPUT The output XLR connector provides a loop trough for speakers daisy chain...

Страница 7: ...THE RCF SERVICE CENTRE 230 Volt 50 Hz SETUP FUSE VALUE T 3 15 AL 250 V 115 Volt 60 Hz SETUP FUSE VALUE T 6 3 AL 250 V The microprocessor is able to signal three different kinds of failure by flashing...

Страница 8: ...prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecch...

Страница 9: ...monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0dB usare solo cavi scherma...

Страница 10: ...se D di RCF permette performance incredibili ed una altissima efficienza in dimensioni e pesi estremamente contenuti Gli amplificatori D LINE sono caratterizzati da attacchi velocissimi risposte ai tr...

Страница 11: ...SCHIO Il connettore XLR di loop del segnale permette la connessione a catena di pi diffusori CONTROLLO DI LIVELLO Varia il volume del diffusore FLAT BOOST Il pulsante imposta l equalizzazione Flat o B...

Страница 12: ...un malfunzionamento grave del diffusore sul modulo amplificatore il LED rosso Limiter lampeggia Il diffusore viene posto in stato mute PRIMA DI CONNETTERE IL DIFFUSORE PRIMA DI ACCENDERE IL DIFFUSORE...

Страница 13: ...as normalement Le cordon secteur est endommag Des objets ou des liquides se sont introduits dans le produit Le produit a subi un choc violent 5 Avant de laisser ce produit inutilis pendant longtemps d...

Страница 14: ...bles blind s et vitez de les faire passer proximit des quipements qui produisent de puissants champs lectromagn tiques des c bles secteur des c bles d enceinte PR CAUTIONS D UTILISATION Placez ce prod...

Страница 15: ...nnect la tension secteur et le commutateur secteur est en position marche ON SORTIE DE SIGNAL SUR ALR M LE Cette sortie sur XLR d livre le signal source non trait pour alimenter d autres enceintes R G...

Страница 16: ...CHNIQUES RCF ALIMENTATION SECTEUR 230 Volt 50 Hz FUSIBLE T 3 15 AL 250 V ALIMENTATION SECTEUR 115 Volt 60 Hz FUSIBLE T 6 3 AL 250 V Le microprocesseur peut identifier trois types d erreurs diff rentes...

Страница 17: ...erden Kontaktieren Sie Ihr autorisiertes Service Center oder qualifiziertes Fachpersonal sollte eines der folgenden Ereignisse auftreten Das Ger t funktioniert nicht oder funktioniert nicht korrekt Da...

Страница 18: ...chen durch Mikrofon oder Linesignalleitungen zu vermeiden verwenden Sie ausschlie lich abgeschirmte Verbindungskabel und platzieren Sie diese nicht in der N he von Ger ten die starke elektromagnetisch...

Страница 19: ...leuchtet gr n wenn das Ger t ans Stromnetz angeschlossen ist der Netzschalter in der Position ON ist und die Schutzschaltung keinen Fehler siehe Fehlermeldungen der Schutzeinrichtungen feststellt M N...

Страница 20: ...ten handelt es sich um WARNUNG ein leichter Fehler oder eine selbst wiederherstellbare Fehlfunktion liegt vor und die Wiedergabe der Lautsprecherbox ist nicht eingeschr nkt SIGNALBEGRENZUNG Limiting d...

Страница 21: ...input output Power input DSP and Protection Circuits PHISICAL SPECIFICATIONS Dimensions w h d Weight Colour 50 20 kHz 129 dB 90 70 1 700 10 2 5 v c 1 1 7 v c 527 303 302 mm 13 9 Kg Black HD 10 A 45 2...

Страница 22: ......

Страница 23: ......

Страница 24: ...0 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcfaudio es RC...