VCD 203

VCD 203

6/16

7/16

Closing edge protection

In  the  "CLOSE"  direction  the  drive  has  an  active 
protection for the main closing edge. If there is an 
overload in the closing ranges 3 and 2, the drive runs 
"OPEN"  for  20  seconds,  then  "CLOSE"  again.  If 
closing is not possible after three attempts, the drive 
remains in this position.
In  addition,  the  drive  is  equipped  with  passive 
protection. The closing speed in closing range 2 and 
1 is reduced to 5 mm/s.

 

  Significantly greater forces can be

 

  exerted at the secondary closing edges.

 

  Danger of crushing hands and fingers!

Stroke limiting with magnets

Voltage must continue to 

be applied to the drive when 
moving in the “CLOSE” 
direction. 

Hold the magnet next 

to the drive as shown in the 
diagramme (2 sec.) until you hear 
a pulsating ton >

 

The

 

drive

 

is

 

now

 

in

 

learning

 

mode

.

 The

 

magnet

 

can

 

now

 

be

 

removed

 

and

 

the

 

drive

 

no

 

longer

 

has

 

to

 

be

 

under

 

voltage

.

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Close drive.

1

Allow the drive to run 

“OPEN” until you reach the 
required stroke.
If the stroke is set incorrectly, 
the procedure is accidentally 
interrupted or the drive 
continues to the full stroke 
length, please return to point 1 
and start again.

STOP

3

learning mode

appr. 2 sec.

2

When using two VCD 203 on one window, both drives must be electrically connected in order to 
set the stroke, although only one drive needs to be switched to the stroke learning mode with the 
magnet.

All approx. 20 % switch-off reserve (temporary)

Running speed and forces

Closure Ranges

~6 mm/s

200 N

5 mm/s

150 N

77 mm

~6 mm/s

200 N

23 mm

Main closing edge

Beside closing edge

Beside closing edge

 ca.120 mm

Type  

 

 

 

VCD 203

Power supply 

 

 

24 V DC / ± 20 %

Nominal current 

 

 

0,35 A

Nominal force 

 

 

200 N

Nominal locking force 

 

approx. 2000 N (Excluding bracket)

Service life   

 

 

>20 000 double strokes

Duty cycle   

 

 

30 % (With cycle time 10 minutes)

Housing 

 

 

 

Zinc-diecasting, powdercoated

Ingress protection   

 

IP 30

Temp. range  

 

 

0 ... +60 °C

Emission sound pressure level 

LpA ≤ 46 dB(A)

/

Nominal stroke length *  **   

250 mm

Additional functions ** 

 

Closing edge protection activated (3 stroke repeatings);

 

 

 

 

 

Locking relief activated

*Adjustable with PLP 1 

** Programmable with PLP 1 and SCS

Technical data

Содержание VCD 203

Страница 1: ...consoles Rogamos que pidan los juegos de fijaci n por separado de Originalbetriebsanleitung Seite 2 Anschluss Seite 14 Abmessungen Seite 16 en Original instructions Page 5 Connection Page 14 Dimensio...

Страница 2: ...i Gefahr durch Regen Regenmelder verwenden Nur unver nderte D H Originalteile verwenden Montageanleitung des Konsolensatzes beachten Beiliegenden roten Sicherheitszettel beachten WARNUNG Lesen Sie all...

Страница 3: ...e auftreten Quetschgefahr im handzug nglichen Bereich Technische Daten Typ VCD 203 Versorgung 24 V DC 20 Nenn Strom 0 35A Nenn Kraft 200 N Nenn Verriegelungskraft ca 2000 N exkl Konsole Lebensdauer 20...

Страница 4: ...3 Am Antrieb muss in ZU Richtung weiter Spannung anliegen Magnet anAntrieb halten ca 2 sek bis nach einem pulsie renden Ton ein Dauerton kommt Antrieb ist imAnlernmodus Der Magnet kann entfernt werde...

Страница 5: ...e carried out only by an authorized electrical specialist Danger of violent pressure in handaccessible area Keep away People from the operating area of the drive Keep away children from the control Us...

Страница 6: ...s and fingers All forces approx 20 switch off reserve temporary Running speed and forces C l o s u r e R a n g e s 6 m m s 2 0 0 N 5 m m s 1 5 0 N 77 mm 6 m m s 2 0 0 N 23 mm Main closing edge Beside...

Страница 7: ...ries According the European Guideline 2012 19 EU for waste electrical and electronic equipment and its implementation into national right electrcal devices that are no longer usable must be collected...

Страница 8: ...orsque le syst me est plac sur des Uniquement utiliser des pi ces d origine D H non modifi es Respecter la notice de montage du kit de console Respecter les indications figurant sur l tiquette de s cu...

Страница 9: ...zone accessible aux mains Toutes les forces env 20 de r serve de coupure En peu de temps Vitesses de courses et forces P l a g e s d e f e r m e t u r e 6 m m s 2 0 0 N 5 m m s 1 5 0 N 77 mm 6 m m s...

Страница 10: ...rique ainsi que leurs accessoires batteries et emballages doivent pouvoir suivre chacun une voie de recyclage appropri e Ne jetez pas votre appareil lectroportatifaveclesorduresm nag res Seulementpour...

Страница 11: ...to bajo Datos t cnicos est en conformidad con las regulaciones 2014 30 EU 2014 35 EU Expediente t cnico en D H MechatronicAG D 22949Ammersbek Dirk Dingfelder Maik Schmees Junta directiva Apoderado Dir...

Страница 12: ...as manos Espa ol Todas las fuerzas aprox 20 de reserva de desconexi n Temporal Velocidades de funcionamiento y fuerzas 99 826 05 1 2 02 20 R a n g o d e c i e r r e 6 m m s 2 0 0 N 5 m m s 1 5 0 N 77...

Страница 13: ...el ctricos accesorios Bater as y embalajes sean sometidos a un proceso de recuperaci n que respete el medio ambiente No arroje las herramientas el ctricas a la basura S lo para los pa ses de la UE Con...

Страница 14: ...rbelegungStecker PinAssigment Brochagedesfiches Asignaci ndecables Mot b BN Mot a WH WH Mot a YE TMS BRV BN Mot b GN SA no GY SA o PK n c SA WH Mot a YE TMS BRV BN Mot b GN SGI GY SGI PK n c SGI WH Mo...

Страница 15: ...Mot a Mot b Gegen Kurzschluss sichern Protect against short circuit Prot ger contre les courts circuits Proteger contra cortacircuitos 1 Antrieb 1 drive 1 motorisation 1 motore BN YE WH Mot b TMS Mot...

Страница 16: ...D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical modifications reserved Sous r serve de modifications techniques Derecho reservado a modificaciones t cnicas 100 Recycl...

Отзывы: