Extended Functions

The following functions are set by the DIP switch S1 on the PCB at the control panel, or can be set by a
D+H distributor with the D+H PDA service tool:

S1.1 ON =

CLOSE

S1.2 ON =

OPEN

S1.2 OFF=

OPEN

Storage operation

S1.1 OFF= Key operation

CLOSE
Storage operation

Key operation

S1.3 ON = activated
S1.3 OFF = deactivated

S1.4 ON = activated
S1.4 OFF = deactivated

S1.5 ON = activated
S1.5 OFF = deactivated

S1.6 ON = activated
S1.6 OFF = deactivated

S1.7 ON = activated
S1.7 OFF = deactivated

S1.8 ON

S1.8 OFF

Programmable by
D+H Distributor with
D+H PDA servicetool

Storage operation

Key operation

Line fault = alarm

Group fault on alarm

OPEN-running time limitation in ventilation operation

Ventilation time limitation

Power failure CLOSED

vent buttons

activitated

vent buttons

deactivitated

deactivated

deactivated

deactivated

activated

activated

Press ventilating button 1 x shortly. The drives/ NSHEVs will open to
their final position.

The drives/NSHEVs will open only as long as the ventilating button is
pressed.

In case of a line fault the control panel will be switched to alarm and the
smoke vent opens (e.g. at an interrupted button line or missing
terminal resistor).

In case of a group fault the control panel will be switched to alarm and
the smoke vent opens (e.g. in case of an interrupted drive line or
missing terminal module).

If the vent button is actuated in direction OPEN, the drives/ NSHEVs
open for 30 s (factory-set). This running time can be edited by D+H
PDA servicetool. Only possible in conjunction with storage operation
in CLOSE-direction.

The drives/ NSHEVs will automatically close again after the time set
(factory-set 10 min). This time can be edited by the D+H PDA
servicetool. Only possible in conjunction with storage operation in
CLOSE direction!

In case of power failure the drives will close. Only possible in
conjunction with storage operation in CLOSE direction!

Integrated

are

Integrated

are

OPEN running time retriggering (factory-set:

)

Group CLOSE in case of alarm (factory-set:

)

Two smoke detectors dependency (factory-set:

)

Smoke detector alarm remote reset (factory-set:

)

Lamp test

Alarm re-clocking (factory-set:

)

Hint: In case of alarm the smoke vent is triggered with an OPEN pulse
every 2 minutes for a duration of 30 minutes according to VdS 2581.
For this, the drive must be protected against blockage according to
VdS 2580 par. 4.7. . All D+H drives meet this precondition.

Содержание RZN 4503-T

Страница 1: ...nnection mounting and functional testing by a specialist company authorized by the manufacturer Green control diodes in the buttons must constantly be on otherwise see Information for Starting Repair...

Страница 2: ...After the maintenance time is expired ca 14 to 16 months the ventilation function OPEN can be interrupted depending on the presetting of the service timer Reset can be carried out by a specialist comp...

Страница 3: ...ensation for damage Therefore regular maintenance and checking of functional readiness is imperative and must be ensured These standard requirements are demanded in accordance with regulations of the...

Страница 4: ...t function CLOSE Fault Charging voltage controller Battery LED system O K DIP switch factory set see p 9 and 11 LED mains LED alarm LED group fault LED battery fault LED earthfault Reset line LED line...

Страница 5: ...BZUG RAUCHABZUG RZN RT 4 click 1 2 4 RAUCHABZUG RAUCHABZUG 3 RZN RT RZN 4503 T Operation Release in case of alarm Manual opening by smoke vent button Automatic opening by fire detector o r a n d Autom...

Страница 6: ...With manual release Opening the housing RZN RT with supplied key Automatic opening by external control see DIP switch S1 page 8 hold for OFF shortly tap for ON 3 s o r o r function is deactivatable b...

Страница 7: ...rtner com Service 12 month 12 month RAUCHABZUG www dh partner com Service 12 month 12 month In case of power failure Emergency closing In case of non resettable alarm hold for OFF 3 s see DIP switch S...

Страница 8: ...and the smoke vent opens e g at an interrupted button line or missing terminal resistor In case of a group fault the control panel will be switched to alarm and the smoke vent opens e g in case of an...

Страница 9: ...tor fault line fault group fault power failure earth fault passing on of central CLOSE ResetAlarm as pulse group closed longer x s Charge temperature guided Monitoring presence final discharging volta...

Страница 10: ...y stage of fire Protected wiring is required with protection against mechanical damages according to DIN 18232 section 2 5 5 paragraph 4 Cable from the smoke vent control panel to connection of drive...

Страница 11: ...ives smoke vent buttons if necessary fire detectors and vent buttons See wiring and connection plans Mounting and Installation Set DIP switch S1 on motherboard as follows Resistor must be cramped in e...

Страница 12: ...detector individual by D H smoke detector tester as an alternative by cigarette smoke response delay circa 20 s Red display diode must be on Smoke vent must open For closing wait until there is no mo...

Страница 13: ...meldezentrale Contact external control e g fire alarm system JY St Y 4x2x0 6 JY St Y 4x2x0 6 JY St Y 2x2x0 6 Zentrale RZN Aufputz 230VAC 24VDC in der N he der RWA Klappe Control panel RZN surface type...

Страница 14: ...cht eingesetzt werden The resistor must not be used when line connections with 2 detector dependency are employed N N A K S Unterbrechertaster Interrupter button Haftmagnet Magnetic clamp Haftmagnete...

Отзывы: