20
For each group the individual plans can be viewed or hidden by tapping on the blue arrow in
the bottom right of the group tile. Swiping the individual plan or group to the left will delete
it, and tapping on them will allow you to make amendments. More than one group of plans
can be added as long as the selected times do not overlap, so for example you could set a
day time plan group and a night time plan group.
Setting the adjustment parameters:
Select ‘Adjust KH’ from the bottom of the custom plan page,
this will take you to the adjust KH settings page.
Note: Automatic adjustments to the dosing schedule will not be active until a test is performed,
triggering the function. A warning ‘”Adjust KH” is ineffective temporarily until complete a KH test’
will be displayed at the bottom of the ‘Adjust KH’ page.
Range:
The KH Manager will only make automatic changes to the dosing if the dKH result
from the test is within a certain range of your KH set point (KH Balance Value), this range can
be programmed to be +/- 0.1 to 1dKH. For example if your KH set point is 7.5 you can set the
machine so that automatic adjustments are made if the dKH tested by the machine is
between 6.5 and 8.5dKH. To Modify the range select ‘Range’ in the adjust KH settings page,
tap on the lower and upper parameters to make adjustments, enter the figure then select
‘Done’ and ‘Save’ in the top right corner to save and exit.
Method:
This is used to determine if you would like the KH Manager to use an amount or
percentage proportion when making the adjustments to the dosing schedule, this
adjustment can be made to effect a single dose on the schedule or multiple doses to spread
and reduce the change in addition. The method currently in use is shown to the right of the
method heading. To change the settings on this or swap between percentage proportion
and amount tap on the ‘Method’ heading and then select either ‘Proportion’ or ‘Amount’
from the pop-up that appears at the bottom of the screen, if you want to exit without
making a change select ‘Cancel’.
o
Proportion
is expressed as a percentage per dKH.
o
Amount
is expressed as
an amount in ml per dKH.
Adjust Times:
Use this to set how many of the plans in the group are adjusted using the
‘Proportion’ or ‘Amount’ methods. If only one plan is adjusted the adjustment is greater
than if multiple plans are adjusted.
Stop Adjusting:
If you want to stop the KH Manager making adjustments
to the plans until
the next KH test is completed, tap on ‘Stop Adjusting’ followed by ‘Stop’ in the pop-up that
appears at the bottom of the screen, to exit without stopping the adjustments select
‘Cancel’. After the next test the machine will resume making adjustments as programmed.