background image

19

Manual del Usuario

 / DXI series / 

User’s Manual

DIRECTLY EDITING AUDIO PARAMETERS (cont'd)

Output High Pass Filter

 

Set the high pass filter frequency – a setting of “<10Hz” bypasses the filter. To change the filter slope 

and type, press ENTER and then adjust with the encoder. Note that 48dB/Octave filters will only be 
available if PEQ 6 & 7 are bypassed.

 

Parametric bands will remember their settings if bypassed and used in 48dB/Octave crossover filters 

and these settings will be reinstated if a lower order filter type is subsequently chosen (24dB/Octave or 
lower).

 

The message 

Out 1  Output 1   

HPF  

25.8Hz   Linkw - Riley 24dB 

 

 

  Bypass PEQ’s 6 & 7
 To Access  48dB Slopes

 

will be shown if the bands aren't already in bypass (or set to 0dB).

Output Low Pass Filter

 

Set the low pass filter frequency – a setting of “>32kHz” bypasses the filter. To change the filter slope 

and type, press ENTER and then adjust with the encoder. Note that 48dB/Octave filters will only be 
available if PEQ 8 & 9 are bypassed.

 

Out 1  Output 1 

LPF

9k70Hz   Linkw - Riley 24dB

 

Parametric bands will remember their settings if bypassed and used in 48dB/Octave crossover filters 

and these settings will be reinstated if a lower order filter type is subsequently chosen (24dB/Octave or 
lower).

 

The message

  Bypass PEQ’s 8 & 9
 To Access  48dB Slopes

 

will be shown if the bands aren't already in bypass (or set to 0dB).

Содержание DX-100I

Страница 1: ...el equipo lea la secci n Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainth...

Страница 2: ...High Pass Filter Output Low Pass Filter Output Parametric EQ Bands 1 through 9 Output Limiters Program Limiter Output Limiters Peak Limiter Output Matrix Gains ADVANCED EDITING FEATURES Overview Selec...

Страница 3: ...calor tales como radiadores calefactores estufas u otros aparatos que produzcan calor No bloquee las aberturas de ventilaci n e instalar de acuerdo con las instrucciones del fabricante Los ventiladore...

Страница 4: ...paraci n en garant a es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing def...

Страница 5: ...us for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances cumplen...

Страница 6: ...th your local power supply requirements but before connecting the unit to the supply ensure that the voltage printed on the rear panel is correct The amplifier is fitted with either a 100 120V or 220...

Страница 7: ...llations which use multiple speakers with electronic crossovers or speaker controllers These systems can handle very high transient signals that far exceed their RMS power rating The DXi series amplif...

Страница 8: ...nating and a corresponding message on the LCD In this way it is possible for two channels a channel pair to remain functioning even though a fault has caused the other channel pair to mute A channel p...

Страница 9: ...BACK and NEXT to choose the Sub Menu and ENTER to select the choice These controls are also used when editing DSP audio parameters accessed via the EDIT keys 13 Signal meters Depending on the current...

Страница 10: ...diagram on page 13 and set up information from page 27 6 Ethernet control port Your amplifier may be remotely controlled by connecting it to a computer via this standard Ethernet port connection Pleas...

Страница 11: ...red remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supplier DO NOT TAMPER WITH OR ALTER ANY GROUND EARTH CONNECTIONSINSI...

Страница 12: ...f the speaker cables will need to be increased above the values quoted here Do not connect the inputs outputs to any other voltage source such as a battery mains source or power supply regardless of w...

Страница 13: ...13 Manual del Usuario DXI series User s Manual DSP LAYOUT CONFIGURATIONS AND ROUTING...

Страница 14: ...l This affects the choices that can be made for routing to the inputs of the DSP channels The rules are as follows Analogue A and B is available at all times If AES A B is selected Analogue C cannot b...

Страница 15: ...te that the mix matrix will only be available if it has been selected as part of the output auxiliary configurations see page 27 to change this Power Amplifier and Auxiliary Output Processing Channels...

Страница 16: ...e if the network outputs are being used to also break in analogue or AES channels for use with other amplifiers it might be more applicable to route the audio from the outputs of input processing chan...

Страница 17: ...e of the parameter You can swap bank at any time by pressing the BANK key and to quickly access the same parameter on another channel within a bank double press on the required channel s EDIT key If t...

Страница 18: ......

Страница 19: ...1 Output 1 HPF 25 8Hz Linkw Riley 24dB Bypass PEQ s 6 7 To Access 48dB Slopes will be shown if the bands aren t already in bypass or set to 0dB Output Low Pass Filter Set the low pass filter frequenc...

Страница 20: ......

Страница 21: ...l not only function incorrectly and not provide the protection you expect it can also sound pretty terrible Setting up limiters has perhaps been seen as a black art by some engineers it is actually a...

Страница 22: ...to Free Assign or a standard routing configuration 1 x 4 way 2 x 2 way etc To use Full Matrix mode please see the section about adjusting the configuration on page 27 Initially the send level from In...

Страница 23: ...r channel C and the AES input for channels C D is on the XLR socket for channel D In this way a pair of analogue inputs can remain connected to channels A B and a digital stream of the same audio can...

Страница 24: ...NEXT keys to cycle between the four combinations of analogue Ana or Digital AES Press ENTER to confirm the choice and again to confirm if changes have been made If a digital source is chosen for eithe...

Страница 25: ...Analogue A Analogue B Analogue C Analogue D And four digital sources depending on the AES selection AES A AES B Dante C Dante D The choices shown above would be shown if AES has been selected on XLR C...

Страница 26: ...tal Outputs Muted The network outputs source is disconnected and no audio is transmitted The Dante connection is maintained and visible on the network Amp Outputs pre Mute Source audio is sourced just...

Страница 27: ...To change configuration from the home screen press MENU choose the CONFIGURATION Sub Menu and press ENTER Use the encoder or BACK and NEXT keys to find the Output Routing option and press ENTER Use t...

Страница 28: ...ved without the automatic gains adjustments by switching to Full Matrix mode and manually setting the send levels as required Select Free Assign mode when changing the output routing separately for po...

Страница 29: ...ng in bridged mode the minimum impedances are doubled The minimum load in bridged mode is 4 ohms For details of how to connect to the amplifier when running in bridged mode please see page 12 Selectin...

Страница 30: ...3 0 and 0dB All output auxiliary channels will also be muted for safety Certain formats will preset the crossover frequencies to give a useful starting point Selecting a 2 x 2 way configuration will...

Страница 31: ...m the lowest member in the gang to all other ganged channels For example adding channel 3 to a gang of 1 3 will instantly make channel 3 s settings identical to channel 1 Mutes remain unganged at all...

Страница 32: ...elays mutes and names for the four input channels Output memories contain all the EQ crossover filters FIR data if applicable polarities gains delays mutes limiters including auto time constants setti...

Страница 33: ...Output Memory STORE an Output Memory Store from Amp Outputs In the previous example the extra step is to choose whether to store the four amplifier outputs data or the four auxiliary outputs data Cho...

Страница 34: ...choose either Input or Output memory type as appropriate and press ENTER RECALL an Output Memory Recall to Aux Outputs Use the encoder to choose the memory required remembering that the list will only...

Страница 35: ......

Страница 36: ...as over temperature threshold or protection triggered and offer simple closed contact control of standby mode mutes or memory recalls It also accepts variable voltages which allow direct level control...

Страница 37: ...Static or Auto IP Auto IP will generate an IP address based on unique hardware features such as MAC address Choose Static if you need to select the IP address to lie within a specific range for insta...

Страница 38: ...at the default of 57600 This is not the actual USB serial data rate it s the virtual COM port data rate RS485 Relay Choose ON to relay all remote control data onto the RS485 network for connection to...

Страница 39: ...te an IP address based on unique hardware features such as MAC address Choose Static if you need to select the IP address to lie within a specific range for instance when working within a larger infra...

Страница 40: ...g this choice will then ask for the following further information to be confirmed RS485 Speed Set RS485 baud rate recommended to use 57600 Remote ID Number Set a device ID still required even on Ether...

Страница 41: ...ifi Router Free yourself of cables and go wireless Plug the Ethernet connection from your amplifier s into a wireless router and you are good to go Main remote configuration of a single amplifier or a...

Страница 42: ...e message Parameters Locked during editing or parameters can be viewed but not adjusted then this is due to preset data locking or hiding and is specific to the currently running preset this is not de...

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ...threshold the engineer registering the situation and then turning the signal down will be in the order of several hundred milliseconds at best This will only be true if he is not distracted in realit...

Страница 48: ...tection against driver overheating and cone over excursion Most speaker systems are given a power rating in Watts RMS This is the maximum continuous power that the system will handle and often appears...

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ...LTAR Amplifier Communications Set up Updates can be performed through an Ethernet US or RS485 connection Choose the correct port on the amplifier and configure it accordingly though the Interface Sub...

Страница 53: ...he Connect Serial button if using USB or RS485 or Connect IP if using an Ethernet connection We recommend you choose either a USB or wired Ethernet connection After a few seconds the unit should be lo...

Страница 54: ...ogress will accompany the bar on the loader app Upon completion the app will close and your amplifier will restart that s it What If It All Goes Wrong Don t panic Your amplifier can be recovered but p...

Страница 55: ...top cover temporarily reapply mains power and switch on Once booted check the interface is set as required and perform a program update again using the Flash Loader application The display will show a...

Страница 56: ...DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134...