False Alarm Filtering Features

2 way voice Intercom on Keypad

Voice Alarm History with Date and Time of zone activation.

Voice Alarm Tracking in real time of activated zones

Alert  zone types  require activation of another zone to trigger a confirmed alarm

Local alarm warning option for delay entry time-out prior to full alarm.

Open- or short-circuit zone condition produces a trouble condition (when 2 end-of-line

resistors are used)

Night Mode Delay zone setting.

Double sign-in of duress code required to generate duress alarm.

Sign-in Codes

16 user codes with individual authorization for arm and disarm, local and remote

access, and disarm after alarm. First 8 user codes for mailboxes

Engineer code for system and security settings.

Sign-in Tamper alarm for protection against repeated sign-in code attempts.

Emergency Buttons

Quick activation of Fire and Panic on keypad.

Test Features

Battery Test - Immediate or at programmed intervals

Security Check  (walk test) zone activation is announced on Keypad

Dial test - dials to all programmed telephone numbers, pagers, Central Stations,

audible on Keypad

Siren Test - Momentary activation

Strobe Test. - turns on and off the strobe.

Engineer Test Mode - allows engineer to work on the system without triggering tamper

or 24 hour alarms.

Event Log

Event Log  accessible by keypad, telephone or Comfigurator software with UCM with

date/time stamp (600 events for Comfort II Ultra, 250 events for Comfort II Optimum)

Local or remote access by telephone.

Select 1st event, last event, previous event , next event , next day, previous day for

quick navigation.

Uploadable to PC using COMFIGURATOR for Windows, may be printed or saved

Other Features

Door Station intercom with home or remote phones (requires Door Station and RGR

Ringer)

Voice Reminder Messages.

Time Programs

User-programmable Timers

Vacation programs in Vacation Mode.

Sunrise/Sunset Times depending on location or City with automatic Daylight saving

time changes.

Remote Programming from any phone with Engineer Sign in code.

EN50131 Compliance (Europe)

The product  CP9000-ULT/EN03 with firmware version 5.106 and above is suitable for use

in systems designed to comply with EN50131 (Europe) and  PD6662:2004 (United

Kingdom) at grade 2 and environmental class II

Ordering Information - Products and Accessories

CP9000-ULT  : Comfort II Ultra with Enclosure, Transformer and User Manual

Comfort II Supplementary Installation Manual

4

Содержание Ultra Comfort II

Страница 1: ...Comfort II Supplementary Installation Manual Comfort the Intelligent Home System...

Страница 2: ...THE PRINTED MANUAL MAY NOT BE THE LATEST VERSION ALWAYS CHECK WWW CYTECH BIZ FOR THE UPDATED VERSION OF THIS MANUAL...

Страница 3: ...LEDs both remain on 13 The Green LED does not blink once after Reset 13 Startup Problems 13 Troubleshooting Kit 13 Section 3 Troubleshooting 12 Remember to set Time and Date 12 Door Station 12 Voice...

Страница 4: ...Comfort II Supplementary Installation Manual 1...

Страница 5: ...atery charger with built in protection against deep discharge of battery shuts down system when battery falls below a threshold preventing damage to the battery Current limited 400 mA battery charging...

Страница 6: ...protected outputs X10 Compatibility Built in two way interface to X10 network via PSC05 110V 60 Hz TW7223 or XM10E 230V 50 Hz module X10 modules not supplied Keypad Door Station Up to 8 Keypads and 3...

Страница 7: ...Test Momentary activation Strobe Test turns on and off the strobe Engineer Test Mode allows engineer to work on the system without triggering tamper or 24 hour alarms Event Log Event Log accessible by...

Страница 8: ...12 V lamps for testing RLY02 8 8 way Reed Relay Module CSM03 PCB Dual Current Sensor PCB supports 2 CSM03 CT sensors CSM03 CT Current Transformer 2 CSM03 CT are connected to 1 CSM03 PCB RC01 YE Yellow...

Страница 9: ...als like presentations tutorials exercises etc which are updated from time to time For Users User Manual with Quick Start Guide The Quick Start Guide gives simple instructions on how to get started wi...

Страница 10: ...es Yes Local Phone Control Yes Yes Remote Phone Access 16 16 User Sign in Codes Yes Yes Sunrise Sunset Daylight saving 16 32 Time Programs 8 16 Reminder Messages Yes Yes Extended X10 codes Send 1 16 R...

Страница 11: ...s with dedicated Tamper Input and Siren Strobe and Speaker outputs A Local Expansion Module provides another 8 inputs and 8 outputs LEM01 or 8 inputs LEM02 in the same enclosure to give a maximum of 1...

Страница 12: ...re cable as well you never know what may be needed in the future If possible use screened cables for trouble free installations Current Consumption It is very easy to underestimate the load which can...

Страница 13: ...r lighting the same external PIRs could be used to operate lighting The prevailing light level can be determined by using a photocell connected to a zone and the corresponding light turned on if it is...

Страница 14: ...The Speaker and Keypad should give a slow beeping tone and any programmed Entry Alert Response should be activated Entry path zones should be announced but not cause an alarm Sign in to disarm to Sec...

Страница 15: ...t the various menus Each key pressed should be followed by a beep tone to show that the key has been recognized Voice Station 1 If there are more than 1 Keypad press F 8 to activate Intercom mode All...

Страница 16: ...efer to the Indicator LEDs table in the previous section The correct sequence should be 1 Both Leds turn on 2 The Red LED goes off after 1 second with the green LED remaining on 3 The Green LED turns...

Страница 17: ...unications Failure The keypad Home LED blinks and Communication Failure ID followed by the ID number is reported upon user sign in This means that a slave device ie Keypad Door Station SEM UCM or RIO...

Страница 18: ...table in Chapter 2 3 Check that the Number of Keypads Location 1675 and Number of Door Stations Location 1674 are correctly set to the number of keypads and Door Stations respectively The Comfort syst...

Страница 19: ...Station or Door Station In Voice Station or Door Station mode if you cannot hear sounds on the keypad or Door Station even if you keep silent i e cannot switch to Listen Mode but the KP or Door Stati...

Страница 20: ...Telephone Line This is usually due to the telephone wiring or a fault on the incoming telephone line Switch off Comfort at the mains and disconnect the battery In this condition the telephone line is...

Страница 21: ...a loss of security as the System is unable to dial out if the parallel phone is offhook This cannot be used for UL systems or monitored systems and is meant for systems concerned mainly with Home Aut...

Страница 22: ...reporting to be aborted as Comfort thinks the phone is offhook The telephone may otherwise seem to be working properly able to make and receive calls System Cannot Dial Out 1 Check that J3 header is...

Страница 23: ...the system must be disarmed before it can be armed again Any attempt to arm when there is an alarm active will result in he message Call Engineer to Reset When arming the keypad beeps rapidly but no Z...

Страница 24: ...their code it will be preceded by time mailbox sign in code OK N A Duress Alarm Doorbell pressed while system is armed N A Doorbell System dial test selected N A Dial Test The system is armed to Day...

Страница 25: ...om Monitoring Station received N A Monitoring Station OK Valid user code 1 16 entered remotely using external phone N A Name Phone Call Sign In Valid user code 1 16 entered using local phone or Keypad...

Страница 26: ...ring a Battery Test F3 1 or the Scheduled Daily Battery Test Configuration Modules Settings Misc Settings Comfort switches off the AC power to the system during the battery test and if the battery vol...

Страница 27: ...phone is used a Phone Trouble alarm will be reported To disable telephone line cut detection refer to Worksheet Table 35 for Location 40 settings One of the settings add 2 is to ignore Line cut After...

Страница 28: ...ber This product must be installed in accordance with the installation instructions contained in this manual CE Marking Europe This equipment complies with the requirements of the EMC Directive 89 336...

Страница 29: ...rt numbers and APB01 3 1 2 6 September 2008 Revised Siren Bellbox Backup Battery Troubleshooting section Rewrite of Quick Start Power On Checklist Added Indicator LEDs Table 3 1 0 21 October 2007 Used...

Страница 30: ...Comfort II Supplementary Installation Manual 27...

Страница 31: ...Comfort II Supplementary Installation Manual 28...

Страница 32: ...ng Fit to Printable Area Select Properties Finishing Tab Document Options Print on Both Sides Booklet Layout Left Side Binding Other printers may have different settings to achieve the same result Com...

Отзывы: