Keypad/ Door Station Problems

Keypad Beeps continuously

If a Keypad is beeping continuously, it means that it has not received any RS485

communications on the KA/KB lines for the last 6 seconds.  The beeps will continue until

any key is pressed or if communication resumes. The beeping does not occur if the unit can

receive communications but is not addressed by the Control panel, due to settings in

Locations 1674 and 1675.

1

Check that the KA/KB are connected to KA/KB on the Comfort panel.

2

Check that the U5 IC (LTC1487) on the Comfort PCB close to the KA/KB terminal block

is installed, and in the right orientation.

3

If

all

 Keypads and Door Stations beep continuously, it means that the problem lies on

the Comfort panel. Check that the U5  IC s inserted in the socket, and there is voltage

12V to 14V on the 12V terminal. Check the state of the RED (D1) and Green (D2) leds

and refer to the section above on Startup problems.

Keypad keys do not beep when pressed

If  the keypad keys  do not give a beep tone when pressed, but there is no  continuous

beeping tone as  described above, the keypad is receiving communications from the control

panel, but its id is not being polled. If there are 10 keys pressed without a poll of that id,

further key presses will not produce beeps.

1

Check that the Keypad/ Door Station selection (JP5) is correctly set to 1-2 (upper

position) for Keypad, and 2-3 (lower position) for Door Station.

2

Check that the ID selection switch SW1 is set to the correct id according to the ID

selection table in Chapter 2.

3

Check that the Number of Keypads (Location 1675) and Number of Door Stations

(Location 1674) are correctly set to the number of keypads and Door Stations

respectively.  The Comfort system must always be reset after changing  these

parameters.

4

Check that the KA and KB connections are not reversed.

Pressing any key gives a long beep

This means that another keypad is being used, intercom or menu mode. Pressing F will end

use of the other keypad, ("thank you, Goodbye").

Cannot Sign in on Keypad

1

Check that the MIC and Voice  are connected to JP15 on the  Control Panel.  If voice is

not heard, the problem is in the Audio path.

2

Check that the COMFIGURATOR interface is not still connected.

3

Check that the Keypad/Door Station ID (SW1) and Keypad/ Door Station selection

(JP5) is correctly set for each Keypad and Door Station.

4

Check that the  Volume Control knob on the Keypad (or the internal trimmer in the

Door Station) is not all the way down.

5

Check that all other Keypads are not in use, for example in Security Check which does

not time out. Press F on the active Keypad to exit.

None of the Indicator LEDs on the Keypad are on

At least one LED should always be on steady or blinking.

1

Check that the 12V and Ground are connected to the corresponding terminals on the

Comfort panel, and the wires are not reversed.

2

Use a multimeter to check that 12V is actually coming to the Keypad

Playback of Recording from the Keypad is Distorted

Usually, this is because the KPMIC Microphone trimmer is set to too high a gain. Reduce the

gain by tuning the KPMIC trimmer lower (clockwise) on  the Control panel. This trimmer is

fixed at the factory from July 2008.

Comfort II Supplementary Installation Manual

15

Содержание Ultra Comfort II

Страница 1: ...Comfort II Supplementary Installation Manual Comfort the Intelligent Home System...

Страница 2: ...THE PRINTED MANUAL MAY NOT BE THE LATEST VERSION ALWAYS CHECK WWW CYTECH BIZ FOR THE UPDATED VERSION OF THIS MANUAL...

Страница 3: ...LEDs both remain on 13 The Green LED does not blink once after Reset 13 Startup Problems 13 Troubleshooting Kit 13 Section 3 Troubleshooting 12 Remember to set Time and Date 12 Door Station 12 Voice...

Страница 4: ...Comfort II Supplementary Installation Manual 1...

Страница 5: ...atery charger with built in protection against deep discharge of battery shuts down system when battery falls below a threshold preventing damage to the battery Current limited 400 mA battery charging...

Страница 6: ...protected outputs X10 Compatibility Built in two way interface to X10 network via PSC05 110V 60 Hz TW7223 or XM10E 230V 50 Hz module X10 modules not supplied Keypad Door Station Up to 8 Keypads and 3...

Страница 7: ...Test Momentary activation Strobe Test turns on and off the strobe Engineer Test Mode allows engineer to work on the system without triggering tamper or 24 hour alarms Event Log Event Log accessible by...

Страница 8: ...12 V lamps for testing RLY02 8 8 way Reed Relay Module CSM03 PCB Dual Current Sensor PCB supports 2 CSM03 CT sensors CSM03 CT Current Transformer 2 CSM03 CT are connected to 1 CSM03 PCB RC01 YE Yellow...

Страница 9: ...als like presentations tutorials exercises etc which are updated from time to time For Users User Manual with Quick Start Guide The Quick Start Guide gives simple instructions on how to get started wi...

Страница 10: ...es Yes Local Phone Control Yes Yes Remote Phone Access 16 16 User Sign in Codes Yes Yes Sunrise Sunset Daylight saving 16 32 Time Programs 8 16 Reminder Messages Yes Yes Extended X10 codes Send 1 16 R...

Страница 11: ...s with dedicated Tamper Input and Siren Strobe and Speaker outputs A Local Expansion Module provides another 8 inputs and 8 outputs LEM01 or 8 inputs LEM02 in the same enclosure to give a maximum of 1...

Страница 12: ...re cable as well you never know what may be needed in the future If possible use screened cables for trouble free installations Current Consumption It is very easy to underestimate the load which can...

Страница 13: ...r lighting the same external PIRs could be used to operate lighting The prevailing light level can be determined by using a photocell connected to a zone and the corresponding light turned on if it is...

Страница 14: ...The Speaker and Keypad should give a slow beeping tone and any programmed Entry Alert Response should be activated Entry path zones should be announced but not cause an alarm Sign in to disarm to Sec...

Страница 15: ...t the various menus Each key pressed should be followed by a beep tone to show that the key has been recognized Voice Station 1 If there are more than 1 Keypad press F 8 to activate Intercom mode All...

Страница 16: ...efer to the Indicator LEDs table in the previous section The correct sequence should be 1 Both Leds turn on 2 The Red LED goes off after 1 second with the green LED remaining on 3 The Green LED turns...

Страница 17: ...unications Failure The keypad Home LED blinks and Communication Failure ID followed by the ID number is reported upon user sign in This means that a slave device ie Keypad Door Station SEM UCM or RIO...

Страница 18: ...table in Chapter 2 3 Check that the Number of Keypads Location 1675 and Number of Door Stations Location 1674 are correctly set to the number of keypads and Door Stations respectively The Comfort syst...

Страница 19: ...Station or Door Station In Voice Station or Door Station mode if you cannot hear sounds on the keypad or Door Station even if you keep silent i e cannot switch to Listen Mode but the KP or Door Stati...

Страница 20: ...Telephone Line This is usually due to the telephone wiring or a fault on the incoming telephone line Switch off Comfort at the mains and disconnect the battery In this condition the telephone line is...

Страница 21: ...a loss of security as the System is unable to dial out if the parallel phone is offhook This cannot be used for UL systems or monitored systems and is meant for systems concerned mainly with Home Aut...

Страница 22: ...reporting to be aborted as Comfort thinks the phone is offhook The telephone may otherwise seem to be working properly able to make and receive calls System Cannot Dial Out 1 Check that J3 header is...

Страница 23: ...the system must be disarmed before it can be armed again Any attempt to arm when there is an alarm active will result in he message Call Engineer to Reset When arming the keypad beeps rapidly but no Z...

Страница 24: ...their code it will be preceded by time mailbox sign in code OK N A Duress Alarm Doorbell pressed while system is armed N A Doorbell System dial test selected N A Dial Test The system is armed to Day...

Страница 25: ...om Monitoring Station received N A Monitoring Station OK Valid user code 1 16 entered remotely using external phone N A Name Phone Call Sign In Valid user code 1 16 entered using local phone or Keypad...

Страница 26: ...ring a Battery Test F3 1 or the Scheduled Daily Battery Test Configuration Modules Settings Misc Settings Comfort switches off the AC power to the system during the battery test and if the battery vol...

Страница 27: ...phone is used a Phone Trouble alarm will be reported To disable telephone line cut detection refer to Worksheet Table 35 for Location 40 settings One of the settings add 2 is to ignore Line cut After...

Страница 28: ...ber This product must be installed in accordance with the installation instructions contained in this manual CE Marking Europe This equipment complies with the requirements of the EMC Directive 89 336...

Страница 29: ...rt numbers and APB01 3 1 2 6 September 2008 Revised Siren Bellbox Backup Battery Troubleshooting section Rewrite of Quick Start Power On Checklist Added Indicator LEDs Table 3 1 0 21 October 2007 Used...

Страница 30: ...Comfort II Supplementary Installation Manual 27...

Страница 31: ...Comfort II Supplementary Installation Manual 28...

Страница 32: ...ng Fit to Printable Area Select Properties Finishing Tab Document Options Print on Both Sides Booklet Layout Left Side Binding Other printers may have different settings to achieve the same result Com...

Отзывы: