background image

DISCLAIMERS

The information in this manual has been carefully checked and 

is believed to be accurate. Cypress Technology assumes no 

responsibility for any infringements of patents or other rights of third 

parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies 

that may be contained in this document. Cypress also makes no 

commitment to update or to keep current the information contained 

in this document.
Cypress Technology reserves the right to make improvements to this 

document and/or product at any time and without notice.

COPYRIGHT NOTICE

No part of this document may be reproduced, transmitted, 

transcribed, stored in a retrieval system, or any of its part translated 

into any language or computer file, in any form or by any means—

electronic, mechanical, magnetic, optical, chemical, manual, or 

otherwise—without express written permission and consent from 

Cypress Technology.
© Copyright 2018 by Cypress Technology.
All Rights Reserved.

TRADEMARK ACKNOWLEDGMENTS

All products or service names mentioned in this document may be 

trademarks of the companies with which they are associated.

Содержание CH-2537TXWPUS

Страница 1: ...CH 2537TXWPUS 4K UHD HDMI VGA over HDBaseT Wallplate Switcher with Signal Event Automation Operation Manual Operation Manual ...

Страница 2: ......

Страница 3: ...echnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expre...

Страница 4: ...hrough any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block any ve...

Страница 5: ... Control 6 6 3 1 Switch Tab 8 6 3 2 Automation Tab 10 6 3 3 EDID Settings Tab 12 6 3 4 System Settings Tab 14 6 4 RS 232 Control 15 6 5 Telnet Control 16 6 6 RS 232 and Telnet Commands 17 7 Connection Diagram 31 8 Specifications 32 8 1 Technical Specifications 32 8 2 Video Specifications 33 8 3 Audio Specifications 34 8 4 Cable Specifications 34 8 5 HDBaseT Features 35 9 Acronyms 36 ...

Страница 6: ...necessary Automatic input detection between the HDMI and VGA inputs with hot plug detection is supported enabling hands free operation A multi function button on the face of the unit provides access to an information OSD as well as allowing manual input selection When paired with a compatible Receiver additional functionality such as EDID management HDCP management and basic signal event automatio...

Страница 7: ... HDMI 2 0 and DVI 1 0 compliant HDCP 2 2 and HDCP 1 x compliant 1 HDMI input 1 VGA input with 3 5mm mini jack audio input Wall plate is designed for US one gang sized enclosures Supports HDMI input resolutions up to 4K 60Hz 4 4 4 8 bit Supports VGA input resolutions up to WUXGA RB Analog stereo audio may be embedded with VGA or DVI HDMI sources HDBaseT output supports resolutions up to 4K 60Hz 4 2...

Страница 8: ...or automatic input selection with hot plug detection Basic signal event automation via RS 232 or CEC w compatible Receiver USB port supports firmware update and powering of 5V 500mA devices Front panel LEDs indicate HDCP mode input source and power Controllable via a multi function front panel button with OSD or via WebGUI Telnet and RS 232 w compatible Receiver only ...

Страница 9: ...is button will switch between the available inputs Pressing and holding this button for 2 seconds will activate the information OSD 5 VGA IN Connect to VGA source equipment such as a PC or laptop 6 HDCP LED This LED indicates the HDCP mode of the current input Green indicates Follow Display mode orange indicates Follow Source mode off indicates HDCP is disabled SRC LED This LED indicates which sou...

Страница 10: ...op box 6 2 Rear Panel 1 2 1 CAT5e 6 7 OUT Connect to a compatible HDBaseT Receiver with a single Cat 5e 6 7 cable for transmission of all data signals 2 DC 12V Connect a 12V DC power adapter to the twin terminal block and connect it to an AC wall outlet for power Optional not required when powered by PoH from the Receiver ...

Страница 11: ...f the listed devices you will be presented with the network details of that particular device 1 IP Mode If you choose you can alter the static IP network settings for the device or switch the unit into DHCP mode to automatically obtain proper network settings from a local DHCP server To switch to DHCP mode please select DHCP from the IP mode drop down then click Save followed by Reboot 2 WebGUI Ho...

Страница 12: ...nd password is admin On the left side of the browser you will see the following menu tabs where all primary functions of the unit Switch Automation EDID Settings and System Settings are controllable via the built in WebGUI The individual functions will be introduced in the following sections Clicking the red Logout tab will automatically log the currently connected user out of the WebGUI and retur...

Страница 13: ...ome active immediately and the routing information displayed on the buttons will change accordingly 1 Output Click on the main button to begin routing selection Click on the Camera icon to mute or unmute the output Click the Edit icon to modify additional Output settings 2 Edit Output This window provides options to rename the Output enable auto switching set audio routing and configure freerun Ou...

Страница 14: ...olor Select the color to display when freerun is active Available choices are Black Red Blue and Colorbars 3 Input Rename either Input or modify the HDCP behavior Input 2 only by clicking on the Edit icon to open the editing window Click on Save to confirm and activate any changes made to a name Changes made to the HDCP behavior are applied immediately Apple Mode Completely disables HDCP support o...

Страница 15: ...e the dropdown to select the Trigger Event to configure Available trigger events are Power On This unit powers on Out A Source Active The currently selected input changes from inactive to active Out A Source Lost The currently selected input changes from active to inactive CEC Enable or disable sending a CEC command when the currently selected Trigger Event is activated Note CEC support must be en...

Страница 16: ...er Delay Set the length of time in seconds that the specified Trigger Event must continue to be true before sending the defined RS 232 command Trigger Wait Set the length of time in seconds to wait after this RS 232 Automation Event has been activated before ANY other Trigger Event can be detected Trigger Command Click the Edit icon to define the RS 232 command to send when the specified Trigger E...

Страница 17: ...preferred name for the User EDID in the space provided then click Save Name to confirm the change Download Click to download and save the current User EDID as a file bin on the connected PC Upload Click to upload a previously saved EDID file bin from the connected PC into the User EDID slot 2 Sink EDID Download Select and save the EDID from a connected display Drop down Menu Select the sink to rea...

Страница 18: ...EDID Source Click the EDID to assign to the selected Input Once the EDID has been selected the change will be occur immediately The EDIDs available in the EDID Source table are EDID Source EDID Content 8bit 2D PCM 1080p 2CH 1080p 60Hz LPCM 2 0 8bit 2D PCM 1080p MCH 1080p 60Hz LPCM 7 1 Bitstream 12bit 2D PCM 4K2K 30 2CH 4K 30Hz LPCM 2 0 12bit 2D PCM 4K2K 30 MCH 4K 30Hz LPCM 7 1 Bitstream 12bit 2D P...

Страница 19: ... any changes made to these settings Note The default password is admin 3 Network The IP Address Netmask and Gateway can be set manually or DHCP can be enabled for automatic IP Configuration if your local network supports it Click on Save to confirm and activate any changes made to these settings Note If the IP address is changed then the IP address required for WebGUI and Telnet access will also c...

Страница 20: ...e unit will automatically reboot 6 4 RS 232 Control Unit Controlling PC Serial Port Settings Pin Definition Pin Definition Baud Rate 19200 1 NC 1 NC Data Bits 8 2 TxD 2 RxD Parity Bit None 3 RxD 3 TxD Stop Bits 1 4 NC 4 NC Flow Control None 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Note RS 232 support requires the use of a compatible HDBaseT Receiver with an RS 232 port ...

Страница 21: ...pe telnet followed by the IP address of the unit and the port number if it is non standard and then hit Enter This will connect us to the unit we wish to control Type help to list the available commands See below for reference Microsoft Windows Version 6 1 7601 Copyright c 2009 Microsoft Corporation All rights reserved C Users Adminstrator telnet 192 168 1 50 23 Note The default IP address is 192 ...

Страница 22: ...e GET MODEL TYPE Show the unit s product type SET FACTORY DEFAULT Reset the unit to its factory defaults SET FACTORY IPCONFIG DEFAULT Reset the unit s IP configuration to the factory defaults SET SYSTEM REBOOT Reboot the unit GET MAC 1 ADDR Show the unit s MAC address SET IP MODE N1 Set the IP address assignment mode Available values for N1 STATIC Static IP mode DHCP DHCP mode GET IP MODE Show the...

Страница 23: ...1 Set the netmask address N1 X X X X X 0 255 GET NETMASK Show the current netmask SET GATEWAY N1 Set the gateway address N1 X X X X X 0 255 GET GATEWAY Show the current gateway SET IN N1 NAME N2 Set the name of input N1 N1 1 2 Input number N2 Name 16 characters max GET IN N1 NAME Show input N1 s current name N1 1 2 Input number SET OUT A NAME N1 Set the name of the output N1 Name 16 characters max...

Страница 24: ...T Show the video type of the output SET OUT A MASK N1 Enable or disable the mask setting on output N1 Available values for N1 OFF Mask disabled ON Mask enabled Note When an output is masked all video including the banner will be blanked out GET OUT A MASK Display the current output mask setting SET OUT AUTO MODE N1 Enable or disable automatic source switching Available values for N1 0 Auto switch ...

Страница 25: ...status of input N1 N1 1 2 Input number Available Responses 0 No sync 1 Sync is present GET OUT A SYNC STATUS Show the current sync status of the output Available Responses 0 No sync 1 Sync is active SET ALL IN EDID MODE N1 Enable or disable using the same EDID for all inputs Available values for N1 ON All mode OFF Appoint mode GET ALL IN EDID MODE Show the current state of the EDID assignment mode...

Страница 26: ...6 12 bit 4K 60 MCH 7 User 1 8 User 2 9 Sink A GET ALL IN EDID Show the current All mode EDID SET IN N1 EDID N2 Assign EDID N2 to input N1 in Appoint mode N1 1 2 Input number Available values for N1 1 8 bit 1080p 2CH LPCM 2 8 bit 1080p MCH 3 12 bit 4K 30 2CH LPCM 4 12 bit 4K 30 MCH 5 12 bit 4K 60 2CH LPCM 6 12 bit 4K 60 MCH 7 User 1 8 User 2 9 Sink A GET IN N1 EDID Show the EDID currently assigned ...

Страница 27: ... N1 NAME Show the current name of user EDID N1 N1 7 8 EDID number SET IN 2 HDCP MODE N1 Set the HDCP mode to use with the HDMI input Available values for N1 0 HDCP disabled 1 Follow source 2 Follow display GET IN 2 HDCP MODE Show the current HDCP mode SET AUDIO OUT A ROUTE N1 Set the audio source to use with the HDMI input Available values for N1 1 HDMI audio 2 Analog audio GET AUDIO OUT A ROUTE S...

Страница 28: ...un disabled GET FREERUN A MODE Show the current state of the freerun function SET FREERUN A TYPE N1 Set the color to display when freerun is enabled and active Available values for N1 1 Black 3 Red 5 Blue 10 Color bar SET FREERUN A TYPE Show the current freerun display color GET FREERUN LIST List all available freerun colors GET AUTOMATION EVENT LIST List all Automation Event types ...

Страница 29: ...F Event disabled GET AUTOMATION EVENT N1 UART Show the RS 232 Automation Event enable state for Trigger Event N1 Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 UART DELAY N2 SEC Set the length of time that the specified Trigger Event must continue to be true before sending the defined RS 232 Automation Event Available values for N1 1 Power on 2...

Страница 30: ...an RS 232 Automation Event has been activated before ANY other Trigger Event can be detected Available values for N1 1 Power on 2 Out A source active 3 Out A source lost N2 1 300 Wait time in seconds Note If both an RS 232 and CEC event is activated by the same Trigger Event the longer of the 2 wait times will be used GET AUTOMATION EVENT N1 UART WAIT Show the wait time for the specified Trigger E...

Страница 31: ...32 characters GET AUTOMATION EVENT N1 UART COMMAND Show the RS 232 Command to be sent when the specified Trigger Event is activated Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 CEC N2 Enable or disable the CEC Automation Event assigned to Trigger Event N1 Available values for N1 1 Power on 2 Out A source active 3 Out A source lost Available v...

Страница 32: ... CEC DELAY N2 SEC Set the length of time that the specified Trigger Event must continue to be true before sending the defined CEC Automation Event Available values for N1 1 Power on 2 Out A source active 3 Out A source lost N2 1 300 Delay in seconds GET AUTOMATION EVENT N1 CEC DELAY Show the delay time for the specified Trigger Event for CEC Automation Available values for N1 1 Power on 2 Out A so...

Страница 33: ... CEC event is activated by the same Trigger Event the longer of the 2 wait times will be used GET AUTOMATION EVENT N1 CEC WAIT Show the wait time for the specified Trigger Event for CEC Automation Available values for N1 1 Power on 2 Out A source active 3 Out A source lost SET AUTOMATION EVENT N1 CEC COMMAND N2 Set the CEC Command to send when the specified Trigger Event is activated Available val...

Страница 34: ...lost SET UART 1 MODE N1 Set the RS 232 operation mode of the unit Available values for N1 1 Console Commands 2 Control GET UART 1 MODE Show the current RS 232 operation mode SET UART 1 BAUDRATE N1 Set the RS 232 baud rate Available values for N1 4800 Baud rate 7200 Baud rate 9600 Baud rate 14400 Baud rate 19200 Baud rate 38400 Baud rate 57600 Baud rate 115200 Baud rate GET UART 1 BAUDRATE Show the...

Страница 35: ...1 DATA BIT N1 Set the number of RS 232 data bits to use N1 5 8 GET UART 1 DATA BIT Show the current RS 232 data bits setting SET UART 1 PARITY N1 Set the parity value for RS 232 Available values for N1 0 None 1 Odd 2 Even GET UART 1 PARITY Show the current RS 232 parity setting Note Commands will not be executed unless followed by a carriage return Commands are not case sensitive ...

Страница 36: ...AM RX HDCP SRC PWR INFO HDMI VGA SERV L R FAC RESET UHD HDMI OVER HDBaseT RECEIVER WITH PoH PoH PSE Power Supply Cat 5e 6 7 Cable HDMI Input VGA Input Stereo Input RS 232 Equipped PC Laptop HDMI Output Media Player PC UHDTV ...

Страница 37: ...ly 48V PoH or 12V 3A DC US EU standards CE FCC UL certified ESD Protection Human Body Model 12kV Air Discharge 8kV Contact Discharge Dimensions 46mm 104mm 67mm W H D Case Only 46mm 104mm 71 5mm W H D All Inclusive Weight 200g Chassis Material Aluminum Silkscreen Color White Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 RH Non condensing P...

Страница 38: ...0 768 60 60 RB 1280 800 60 60 RB 75 1280 960 60 1280 1024 60 75 85 1366 768 60 60 RB 1440 900 60 60 RB 1600 1200 60 1680 1050 60 60 RB 1920 1200 60 RB Supported TV Resolution Hz HDMI Input VGA Input HDBaseT Output 720 480p 60 720 576p 50 1280 720p 50 60 1920 1080i 50 60 1920 1080p 24 25 30 50 60 3840 2160p 24 25 30 4096 2160p 24 25 30 3840 2160p 50 60 4 2 0 4096 2160p 50 60 4 2 0 ...

Страница 39: ...e Specifications HDMI Cable Length 1080p 4K 8 bit 12 bit 8 bit Input 15m 10m 5m Output 15m 10m 5m Cat Cable Length 1080p 4K Cat 5e 100m 70m Cat 6 100m 70m Cat 7 100m 100m Full HD Video 1080p Up to 1080p 60Hz 12 bit color Data rates lower than 5 3Gbps or below 225MHz TMDS clock Ultra HD Video 4K 4K 24 25 30Hz 4K 50 60Hz YUV 4 2 0 8 bit color Data rates higher than 5 3Gbps or above 225MHz TMDS clock...

Страница 40: ...35 8 5 HDBaseT Features HDBaseT Feature Supported Video Audio IR Pass through RS 232 Pass through Accept power from Receiver Send power to Receiver LAN Pass through ...

Страница 41: ...tection HDMI High Definition Multimedia Interface HDR High Dynamic Range HDTV High Definition Television LED Light Emitting Diode LPCM Linear Pulse Code Modulation PC Personal Computer PD Powered Device PoH Power over HDBaseT PSE Power Sourcing Equipment UHD Ultra High Definition UHDTV Ultra High Definition Television USB Universal Serial Bus VGA Video Graphics Array WUXGA RB Widescreen Ultra Exte...

Страница 42: ......

Страница 43: ......

Страница 44: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw ...

Отзывы: