10
6.3.2 Automation Tab
The Automation tab provides control over the unit’s automatic control
command broadcast behavior when the specified system trigger
events occur. Automation commands may be sent to 3rd party
devices via standard CEC, or customizable RS-232.
Note: Sending RS-232 commands requires the use of a compatible
HDBaseT Receiver with an RS-232 port.
1) Trigger Event:
Use the dropdown to select the Trigger Event to
configure. Available trigger events are:
– Power On:
This unit powers on.
– Out A Source Active:
The currently selected input changes
from inactive to active.
– Out A Source Lost:
The currently selected input changes
from active to inactive.
■ CEC:
Enable or disable sending a CEC command when the
currently selected Trigger Event is activated.
Note: CEC support must be enabled on the connected HDMI
device.
■ Trigger Delay:
Set the length of time, in seconds, that the
specified Trigger Event must continue to be true before sending
the defined CEC command.