14
SV130 SV150 Installation - English
REMOTE CONTROL
1
- operation of all the ventilators connected in series is determined by the CN7 jumper position.
Speed selection
Natural Air Supply
The shutters are open, the fan does not
run.
Night mode
in the darkness.
Air supply
The ventilator continually supplies fresh
air to the room irrespective of the CN7
jumper position.
Regeneration
The ventilator switches between supply
and extract modes each 70 seconds with
heat regeneration.
The ventilator operates at the selected
speed either in extract or supply mode
depending on the CN7 jumper position.
Humidity Set Point Setting
Set the speed switch to position and the ventilation mode switch to position to enable remote control of the ventilation unit.
1. Turning the ventilator on / off .
ON/OFF
ON/OFF
If the Night mode is activated, the ventilator switches to the first speed in the darkness when the light is turned off. Activation of the Night
mode is confirmed by a long sound signal. Exiting the Night mode is confirmed by a short sound signal.
3. Speed selection.
- First speed
- Second speed
- Third speed
4. Operation mode.
- Natural Air Supply mode. The room is ventilated in the natural way, the fan is off.
- Air Supply mode. Air is supplied to the room at a set speed. All ventilators connected in series operate in air supply
mode no matter of CN7 jumper position.
- Ventilation mode. Air is extracted (factory setting) or supplied at a selected speed. All the ventilators connected in
series operate depending on position of CN7 jumper.
- Regeneration mode. The ventilator operates 70 seconds in supply mode and then 70 seconds in extract mode with
heat regeneration.
5. Humidity Control mode.
Humidity control is possible only in Regeneration mode by pressing one of the buttons that allow to select the humidity set point. In the
Humidity Control Mode the ventilator measures the humidity of the extract air. If the humidity exceeds the selected set point the ventilator
switches to a higher speed. After reaching the required level of humidity the ventilator switches to a lower speed. Press one of the speed
switches to deactivate the Humidity Control mode.
- Setting humidity set point - 45%
- Setting humidity set point - 55%
- Setting humidity set point - 65%
HUMIDITY CONTROL MAY BE ACTIVATED WITH THE REMOTE CONTROL ONLY!