![CYBEX XP4010 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/cybex/xp4010/xp4010_installer-user-manual_2703692062.webp)
5 6
8
7
6
5
4
3
2
1
O
N
EXP ANSION REMOTE USER
TRANSMITTER
PWB: 016-0102 REV . A
JP1
JP5
JP9
JP13
JP17
JP21
JP26
JP2
JP6
JP10
JP14
JP18
JP22
JP3
JP7
JP11
JP15
JP19
JP23
JP4
JP8
JP12
JP25
JP16
JP20
JP24
8
7
6
5
4
3
2
1
O
N
DIP SWITCH
DEFAULT
Before installing your transmitter and receiver boards in your XP4000 system,
you will need to configure them for your system requirements. There are two
steps to configuring your expansion boards:
1) Configuring the 8-position DIP switch on the transmitter boards with a
unit address.
2) Configuring the jumpers on the transmitter and receiver boards for your
specific expansion cable length.
Please note that the same settings apply to both the standard and Category 5
expansion transmitter and receiver cards.
Configuring the Transmitter DIP Switch
All units that contain transmitters must be given a unique unit address that you
determine. Unit addresses are numeric, and may be any value between 1 and
254. Please note that unit addresses of “0” and “255” are reserved. Every
transmitter in a given unit must be configured for the same unit address for
proper operation.
To set the DIP switch on your transmitters, follow the steps below:
1) Locate all of the transmitters that will be installed in a single XP4000
Series unit.
2) Orient your first transmitter board as shown below, and locate the colored
DIP switch assembly.
3) Choose a unique unit address and configure your transmitter board according
to the table below. For unit addresses higher than 12, see Appendix H.
4) Configure every remaining transmitter board for this specific XP4000
Series unit with the same address.
5) Set these transmitters by the applicable XP4000 Series unit. Locate all
transmitters that will be installed in your next XP4000 Series unit, and
repeat steps 2 - 5 until you have reached the last XP4000 Series unit in
your system.
Transmitter/
Receiver Board
Configuration
Unit
(8 ------ 1)
Unit
(8 ------- 1)
Address
Setting
Address
Setting
1
00000001
7
00000111
2
00000010
8
00001000
3
00000011
9
00001001
4
00000100
10
00001010
5
00000101
11
00001011
6
00000110
12
00001100