CyberPower PR5000ELCDRTXL5U Скачать руководство пользователя страница 8

 

 

 

 

MULTIFUNCTION LCD READOUT

 

 

 

 

 

 

 

 

BASIC OPERATION

Screen toggle –

 

To toggle through the status screens press the Select button which is located directly next to the 

LCD.

 

Screen illumination–

 

After  30  seconds  of  inactivity,  the  LCD  backlight  will  automatically  turn  off  to  conserve 

energy. Keeping the LCD screen lit at all times is not an option on this UPS.

 

Select Button

 

 

If  the  LCD  screen  is  not  lit  pressing  the  Select  button  once  will  turn  the  LCD  on.  If  the  LCD  screen  is  lit,  then 
pressing the Select button once will toggle through the status screens. 

 

Pressing and holding the Select button for four (4) seconds while UPS is in Normal operation will initiate the Self 
Test.     

 

Pressing and holding the Select button for four (4) seconds while UPS is in Battery/Offline mode will activate Silent 
Mode on the UPS.

 

 

 

MAIN FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The  multifunction  LCD  readout  provides  ready  access  to  power/battery  condition  vitals,  such  as: 
Runtime, Load, Temperature, and much more. 
The  screen  is  also  rotatable  so  the  UPS  can  be  used  in  either  rack  mount  or  vertical/tower 
orientation. 

   

Select Button 

DEFINITION FOR ILLUMINATED LCD INDICATORS

 

Load  Level:

  The  total 

load  of  the  connected 
equipment  shown  in 
20% increments.

 

Battery  Capacity:

  The 

battery’s  current  charge 
level  shown  in  20% 
increments.

 

Fault icon:

 This icon appears if there is 

an internal problem with the UPS. 
Please contact Technical Support if 
this icon is lit. 

Normal  Icon:

  This  icon 

appears  when  the  UPS 
is  working  under  normal 
conditions.

 

 

Battery  Icon:

  This  icon  appears  when  the  UPS  is 

operating  using  battery  power.  The  UPS  will  also 
sound alarms (two short beeps followed by a pause) 
when this icon is lit. When the Battery Icon is lit and 
the  Battery  Capacity  falls  to  20%  the  frequency  of 
the  alarms  will  increase  indicating  that  the  UPS 
batteries are nearly out of power. If this occurs, it is 
recommended  that  you  either  restore  AC  power,  or 
manually  power  down  your  equipment  that  may  be 
negatively affected by sudden power loss.

 

Automatic Voltage Regulation (AVR) icon:

 This icon 

appears  when  the  UPS  is  automatically  correcting 
AC  input  line  voltage  without  using  battery  power. 
This  is  a  normal,  automatic  operation  of  your  UPS, 
and  no  action  is  required.  The  AVR  in  this  UPS 
continuously  conditions  the  power  to  a  nominal 
220/230/240V output to connected equipment. In the 
event of a complete power loss, severe brownout, or 
over  voltage,  the  UPS  relies  on  its  internal  battery 
back up to supply a consistent 220/230/240V output. 

Silent  icon:

  This  icon  appears  when  the 

UPS is in silent mode. During Silent mode, 
the  unit’s  alarm  does  not  sound  until  the 
Battery Capacity falls to < 20%. 

 

Overload  icon:

  This  icon  appears 

when the Battery/Surge outlets on the 
UPS  are  overloaded.  The  UPS  will 
also  sound  an  alarm  at  this  point.  To 
clear the overload, the total load of the 
connected  equipment  must  be  less 
than  the  unit’s  maximum  capability. 
The  easiest  way  to  correct  this 
problem  is  to  remove  noncritical 
equipment  from  the  Battery/Surge 
outlets. 

7

 

Содержание PR5000ELCDRTXL5U

Страница 1: ...User s Manual PR5000ELCDRTXL5U PR6000ELCDRTXL5U K01 0000166 00...

Страница 2: ...quipment to connect the UPS to the AC outlet CAUTION Please use only VDE tested CE marked power cables to connect any equipment to the UPS CAUTION When installing the equipment ensure that the sum of...

Страница 3: ...ll sound and the UPS will emit one long beep In order to reset it turn the unit off and unplug some equipment from outlets Make sure your equipment carry a load current within the unit s safe range re...

Страница 4: ...ovide output overload and fault protection 8 Input Terminal Block Use this terminal to connect the UPS System to utility power Typical wire size is 10 AWG 9 Input Circuit Breaker The circuit breaker s...

Страница 5: ...wer cord to avoid damaging your equipment and avoid fire hazards CAUTION Wiring must be done by qualified personnel INPUT TERMINALS OUTPUT TERMINALS HARDWIRE THE INPUT OUTPUT TERMINALS 4 1 Turn the kn...

Страница 6: ...rews Step 3 Rack mount rail Installation Ensure rack stability prior to installing devices in the rack Attach the rack mount rails to your rack using fasteners that are designed for your rack system S...

Страница 7: ...the UPS you are now ready to plug in the UPS and attach your equipment SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conduc...

Страница 8: ...lit Normal Icon This icon appears when the UPS is working under normal conditions Battery Icon This icon appears when the UPS is operating using battery power The UPS will also sound alarms two short...

Страница 9: ...oad Current Level screen this displays the total load current of the connected equipment expressed as a percentage Battery Capacity The Battery Capacity screen displays the battery s current charge le...

Страница 10: ...will adjust the UPS shutdown point according to the battery s remaining capacity These programmable items are sorted by unit as in the following table Step 3 Press and hold the display toggle for 4 s...

Страница 11: ...as jewelry chains wrist watches and rings CAUTION Do not open or mutilate the batteries Electrolyte fluid is harmful to the skin eyes and may be toxic CAUTION To avoid electrical shock turn off and un...

Страница 12: ...ernal Current Limiting Data line Protection Surge Protection 2430Joules 2430Joules Phone Network Protection RJ11 RJ45 One In One Out Battery Specifications 16 12V 9 0AH Sealed Maintenance Free Yes Use...

Страница 13: ...arged Recharge the batteries by leaving the UPS plugged in Batteries are degraded Contact CyberPower for repair The UPS will not turn on The on off switch is designed to prevent damage by rapidly turn...

Отзывы: