Model 

PR5000ELCDRTXL5U 

PR6000ELCDRTXL5U 

Configuration 

 

Capacity (VA) 

5000VA 

6000VA 

 

Capacity (Watts) 

4000W 

4500W 

 

Energy-saving Technology 

GreenPower UPS™ Bypass 

Input 

 

Nominal Input Voltage 

230V                                                                                                                           

 

Input Voltage Range 

159-288V 

 

Input Adjustable Voltage Range 

151-302V 

 

Frequency Range 

50/60Hz +/- 3Hz 

 

Input Plug Type 

(1) Terminal block     

 

Cold Start 

Yes 

Output 

 

Output Voltage Note 

Configurable for 220/ 230/ 240 nominal output voltage 

 

UPS Outlets 

(8) IEC C 13, (2) IEC C19, (1) Terminal block 

 

On Battery Output Voltage 

Pure Sinewave, 230V +/- 5% 

 

On Battery Output Frequency 

50Hz+/- 0.1Hz 

 

Transfer Time (Typically) 

4ms 

 

Overload Protection 

On Utility: Circuit Breaker; On Battery: Internal Current Limiting 

Data line Protection 

 

Surge Protection 

2430Joules 

2430Joules 

 

Phone / Network Protection 

RJ11/RJ45 (One In/One Out) 

Battery 

 

Specifications 

(16) 12V/9.0AH 

 

Sealed, Maintenance Free 

Yes 

 

User Replaceable 

Yes 

 

Recharge Time (Typically) 

4 hours   

Status Indicators 

 

Indicator LEDs 

Power On, LCD Display (Using Battery, AVR, Load Level, Battery Level) 

 

Audible Alarms 

On Battery, Low Battery, Overload 

Environment

 

 

Operating Temperature 

32

 to 104

 ( 0

 to 40

 

Operating Relative Humidity 

0 to 95% Non-Condensing 

Management

 

 

On-Device Features 

Self Test, Auto-Charge, Auto-Restart 

 

Connectivity Ports 

(1) USB, (2) Serial 

 

SNMP/HTTP Capable 

Yes [With optional RMCARD 202] 

Software

 

 

Power Management Software 

PowerPanel

®

 Business Edition 

Physical

 

 

Dimensions (LxWxH) (mm) 

640 x 430 x 222 

 

Weight (kg) 

101 

103 

Safety

 

 

Conformance Approvals 

CE, C-tick 

TECHNICAL SPECIFICATIONS

 

11

 

Содержание PR5000ELCDRTXL5U

Страница 1: ...User s Manual PR5000ELCDRTXL5U PR6000ELCDRTXL5U K01 0000166 00...

Страница 2: ...quipment to connect the UPS to the AC outlet CAUTION Please use only VDE tested CE marked power cables to connect any equipment to the UPS CAUTION When installing the equipment ensure that the sum of...

Страница 3: ...ll sound and the UPS will emit one long beep In order to reset it turn the unit off and unplug some equipment from outlets Make sure your equipment carry a load current within the unit s safe range re...

Страница 4: ...ovide output overload and fault protection 8 Input Terminal Block Use this terminal to connect the UPS System to utility power Typical wire size is 10 AWG 9 Input Circuit Breaker The circuit breaker s...

Страница 5: ...wer cord to avoid damaging your equipment and avoid fire hazards CAUTION Wiring must be done by qualified personnel INPUT TERMINALS OUTPUT TERMINALS HARDWIRE THE INPUT OUTPUT TERMINALS 4 1 Turn the kn...

Страница 6: ...rews Step 3 Rack mount rail Installation Ensure rack stability prior to installing devices in the rack Attach the rack mount rails to your rack using fasteners that are designed for your rack system S...

Страница 7: ...the UPS you are now ready to plug in the UPS and attach your equipment SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conduc...

Страница 8: ...lit Normal Icon This icon appears when the UPS is working under normal conditions Battery Icon This icon appears when the UPS is operating using battery power The UPS will also sound alarms two short...

Страница 9: ...oad Current Level screen this displays the total load current of the connected equipment expressed as a percentage Battery Capacity The Battery Capacity screen displays the battery s current charge le...

Страница 10: ...will adjust the UPS shutdown point according to the battery s remaining capacity These programmable items are sorted by unit as in the following table Step 3 Press and hold the display toggle for 4 s...

Страница 11: ...as jewelry chains wrist watches and rings CAUTION Do not open or mutilate the batteries Electrolyte fluid is harmful to the skin eyes and may be toxic CAUTION To avoid electrical shock turn off and un...

Страница 12: ...ernal Current Limiting Data line Protection Surge Protection 2430Joules 2430Joules Phone Network Protection RJ11 RJ45 One In One Out Battery Specifications 16 12V 9 0AH Sealed Maintenance Free Yes Use...

Страница 13: ...arged Recharge the batteries by leaving the UPS plugged in Batteries are degraded Contact CyberPower for repair The UPS will not turn on The on off switch is designed to prevent damage by rapidly turn...

Отзывы: