Input  voltage  meter:

  This  meter  measures  the  AC  voltage  from  the  wall  outlet.  The  INPUT  voltage 

readout is used to identify the input voltage information. When the UPS connects to any equipment, the 

AVR can provide a stable 220/230/240V power output.    In the event of a complete loss of power, severe 
brownout,  or  over  voltage,  the  UPS  relies  on  its  internal  battery  to  back  up  to  supply  a  consistent 

220/230/240V output. 

2. 

Output voltage meter:

 This meter measures the output voltage from the UPS. 

3. 

Estimated Run Time:

 This displays the estimated UPS runtime based on current load. When runtime 

becomes shorted, the battery capacity will decrease; (battery capacity bar indicator will be falling). 

4. 

Normal mode icon:

 This icon illuminates when the UPS is working under normal conditions. 

5. 

Battery icon:

 When there is a severe brownout or blackout, this icon will appear followed by an alarm, 

(two short beeps), indicating that the UPS is now working using its internal batteries. Once the batteries 

are run out of power, (over a period of time), a constant alarm will sound. If this happens and main power 

has not been restored, it is recommended that you save your files and turn off your equipment manually 

as soon as possible. 

6. 

Silent  mode  icon:

  This  icon  appearing  indicates  that  the  buzzer  will  not  be  beeping  while  in  battery 

operating mode.

 

During Silent mode, the unit’s alarm does not sound until the Battery Capacity falls to < 

20%. 

7. 

Over  load  icon: 

This  icon  will  appear  followed  by  an  alarm,  indicating  that  an  overload  condition  has 

been reached.  To recover  from the overload  condition, start unplugging  your equipment  from  the UPS 
outlets until the icon disappears and the alarm stops. 

8. 

BATT. CAPACITY:

 BATT. CAPACITY is shown as a bar chart; each segment indicates approximately a 

20% of battery capacity.   

9. 

LOAD CAPACITY:

 Load CAPACITY is shown as a bar chart; each segment indicates approximately a 

20% of load capacity.   

 
 

 

 

 
 

 

 

 

 

1  

2  

3  

4  

5  

6  

7  

8  

9  

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

Содержание Nitram ELITE PRO 1000ELCDRT1U

Страница 1: ...User s Manual ELITE PRO Series ELITE PRO 750ELCDRT1U ELITE PRO 1000ELCDRT1U K01 2F01011 02 EN...

Страница 2: ...accordance to CE requirements CAUTION The AC outlet where the UPS is connected should be close to the unit and easily accessible CAUTION Please use only VDE tested CE marked mains cable e g the mains...

Страница 3: ...IDE 1 Battery charge loss may occur during shipping and storage For the first time the UPS is used it is strongly recommended to charge batteries for at least four hours in order to ensure maximum cap...

Страница 4: ...low connection and communications between the UPS and any attached computer The primary computer the one with PowerPanel Business Edition S W installed is the computer that you will use to control the...

Страница 5: ...type of control takes place with the use of the provided PowerPanel Business Edition S W 6 AC Inlet Connect the AC Power cord to a properly wired and grounded outlet 7 Input Circuit Breaker This circu...

Страница 6: ...dispose of batteries on fire since they may explode Follow all local ordinances regarding the proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful...

Страница 7: ...regulations Remove the front panel on the right side Remove the two retaining screws of the cable protection cover and then remove the cover itself Disconnect the black and red wires from the battery...

Страница 8: ...two short beeps indicating that the UPS is now working using its internal batteries Once the batteries are run out of power over a period of time a constant alarm will sound If this happens and main p...

Страница 9: ...f test X V V X overload V X V V Battery Mode Select SW Press UPS Status Display Capacity Display Digital Value Display Load Cap Battery Cap Input Voltage Output Voltage Run Time of Load of Battery Ini...

Страница 10: ...Frequency Tolerance There are 5 different settings 0 25 0 5 1 2 4 Hz Sec The fault value is 4Hz sec Functional Description Slew Rate indicates the tolerance of a device in accepting frequency variance...

Страница 11: ...670 Input Nominal Input Voltage 220Vac 240Vac Input Voltage Range 160Vac 290Vac Input Frequency Range 50 60 Hz 3 Hz auto sensing Output On Battery Output Voltage Pure Sine Wave at 230Vac 5 On Battery...

Страница 12: ...support techinque nitram fr The UPS will not turn on The on off switch is designed to prevent damage by rapidly turning it off and on Turn the UPS off Wait 10 seconds and then turn the UPS on The unit...

Страница 13: ...Manuel d utilisation UPS onduleur professionnel au format Rack 19 1U ELITE PRO 750ELCDRT1U ELITE PRO 1000ELCDRT1U FR...

Страница 14: ...urce lectrique CA avant toute maintenance de la batterie ou installation d un composant informatique ATTENTION Pour r duire les risques d incendie connecter l onduleur un circuit de 16 amp res de cour...

Страница 15: ...ition se connecte sur le port USB ou sur le port s rie de l onduleur Il peut contr ler la planification du fonctionnement le test de la batterie la prise de courant etc et obtenir des informations sur...

Страница 16: ...t d urgence Utilisez le c ble gris fourni pour le connecter un commutateur contact EPO sp cial Suivez le sch ma de c blage appropri ci dessous pour relier le c ble votre configuration EPO Le commutat...

Страница 17: ...ne de courant prolong e Ce type de commande se fait via le logiciel PowerPanel Business Edition fourni 6 Entr e AC Connectez le c ble d alimentation pour alimenter l onduleur 7 Disjoncteur d entr e Le...

Страница 18: ...les concernant l limination appropri e des batteries Presque tous les revendeurs de batteries au plomb peuvent collecter les batteries usag es pour le recyclage comme cela est requis par la loi de la...

Страница 19: ...er le panneau avant sur le c t droit 2 Enlever les deux vis de fixation du capot du c ble de protection puis enlever le capot lui m me 3 D brancher les fils noir et rouge de la batterie 4 Enlever les...

Страница 20: ...uleur utilise maintenant ses batteries internes Une fois que les batteries sont court de puissance sur une certaine dur e une alarme retentit Si ceci se produit et que l alimentation secteur n a pas t...

Страница 21: ...X V 5 me Retour X V X V V Appui 4sec Son d sactiv X V V X Nouvel appui 4sec Son activ X V X X Surcharge X V V V Interrupteur S lection Appuyez sur Affichage tat onduleur Affichage capacit Affichage va...

Страница 22: ...ge peut tre ajust en fonction de la qualit de l lectricit utilis e d Vitesse de mont e Aussi connu sous le nom de Tol rance de fr quence dynamique Il y a 5 r glages diff rents 0 25 0 5 1 2 4 Hz Sec La...

Страница 23: ...T1U ELITE PRO 1000ELCDRT1U Puissance VA 750VA 1000VA Puisance Watts 500 670 Entr e Tension nominale 220Vac 240Vac Plage de tension 160Vac 290Vac Plage de fr quence 50 60 Hz 3 Hz d tection automatique...

Страница 24: ...enti rement charg es Rechargez les batteries en laissant l onduleur branch Les batteries sont d grad es Contactez NITRAM CyberPower pour le remplacement des batteries sur support technique nitram fr...

Отзывы: