CPS1500PIE 

 

Copyright ©  2014 CyberPower Systems, Inc.

 

 

DEFINITIONS FOR ILLUMINATED LCD

 

 

 

 

Definitions for illuminated LCD 

The LCD Display indicates a variety of EPS operational conditions. All descriptions apply when the EPS 

is plugged into an AC outlet and turned on or when the EPS is on battery.

 

 

 

1. INPUT VOLTAGE Meter:

 This meter measures the AC 

voltage that the EPS is receiving from the utility wall outlet. 

The  EPS  is  designed,  through  the  use  of  automatic 

voltage  regulation,  to  continuously  supply  connected 

equipment with stable 220 output voltage. In the event of a 

complete  power  loss,  severe  brownout  or  over-voltage, 

the EPS will rely on its

 external battery t

o supply consistent 220 output voltage. The Input Voltage Meter 

can be used as a diagnostic tool to identify poor quality input power. 

 

2.  OUTPUT  VOLTAGE  Meter: 

This  meter  measures,  the  AC  voltage  that  the  EPS  is  providing  to  the 

connected equipment. It displays normal line mode, AVR mode, and battery backup mode. 

 

3. NORMAL MODE Icon:

 This icon will illuminate when the EPS is working under normal conditions. 

 

4. ON BAT (On Battery) Icon:

 When a severe brownout or blackout occurs, this icon illuminates and an 

alarm  sounds  (2  short  beeps  followed  by  a  pause)  to  indicate  the  EPS  is  operating  from  it

s  external 

batteries.

  During  a  prolonged  brownout  or  blackout,  the  alarm  will  sound  continuously.  When  the 

BATTERY CAPACITY Meter shows one 25% capacity segment remaining it indicates the EPS's external 

batteries are nearly out of power. You should save files and shut down your equipment immediately. 

 

5. SILENT MODE  Icon: 

This  icon  illuminates  whenever  the  EPS  is  in  silent  mode.  The  buzzer  will  not 

beep during the battery mode until the battery reaches low capacity. 

 

6. OVER LOAD Icon: 

This icon  will illuminate and an alarm  will sound to indicate the battery supplied 

outlets are overloaded. To clear the overload, unplug some of your equipment from the battery supplied 

outlets until the icon is no longer illuminated and the alarm stops. 

 

7. LOAD CAPACITY Meter: 

This meter displays the approximate output load level (in 25% increments) of 

the EPS's battery outlets. 

 

8. BATTERY CAPACITY Meter: 

This meter displays the approximate charge level (in 25% increments) of 

the EPS's external battery. During a blackout or severe brownout, the EPS will switch to battery power, 

the ON BAT icon will be illuminated and the charge level will decrease.

Содержание CPS1500PIE

Страница 1: ...User s Manual CPS1500PIE K01 0000133 03 EN CyberPower Systems Inc Website www cpsww com...

Страница 2: ...equipment CAUTION To reduce the risk of fire only connect the EPS to a circuit with 16 amperes CPS1500PIE Series maximum branch circuit over current protection in accordance with the CE requirement C...

Страница 3: ...emands of these devices will overload and possibly damage the unit DO NOT INSTALL THE EPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR HEAT DO NOT BLOCK OFF VENTILATION OPENINGS IN THE EPS S H...

Страница 4: ...the ON and OFF positions 2 DO NOT plug a laser printer paper shredder copier space heater vacuum or other large electrical device into the EPS The power demand of these devices may overload and damag...

Страница 5: ...put of 1b is 12A for UK socket 16A for Schuko France socket Max Output wattage of 1a 1b is 1050W Note Maximum cord length is 10 meters and the cable O D must be 14AWG 2 AC Inlet AC input terminals Not...

Страница 6: ...Output Selector The unit has specific Bypass function Bypass The switch provides the bypass for charge only and shutdown the unit when the utility power exceeds 300Vac or below 140Vac In charger only...

Страница 7: ...ssionals 1 Remove the cover from the back of the machine 2 Make sure the POWER SW Output Selector and the BATTERY SW are turned off Step1 3 Connect the AC OUTPUT connections AC plugs or terminal conne...

Страница 8: ...isplay toggle Selected Switch once The output voltage showing on the LCD Module Display should be 220V This completes the start up process Step 6 9 Press and hold the Display toggle switch for 4 secon...

Страница 9: ...on When a severe brownout or blackout occurs this icon illuminates and an alarm sounds 2 short beeps followed by a pause to indicate the EPS is operating from its external batteries During a prolonged...

Страница 10: ...2 Set up Mode Step 1 The machine enters Set up Mode after the Display Toggle is pressed and held for 10 seconds When icons 1 2 see page 8 all illuminate the EPS is in the Set up mode Step 2 By pressin...

Страница 11: ...tage supplied in the area country where the EPS will be used Default 220V Choice 220 230 240V e Static Frequency Tolerance The settings may be adjusted to the quality of the electricity in use Default...

Страница 12: ...ont panel for 10 seconds and let the EPS enter Set up Mode Step 2 By pressing the Display Toggle switch setup function to Battery Capacity Charging Current Step 3 Press and hold the toggle for 4 secon...

Страница 13: ...more information please contact the local agent CAUTION BATTERY LIFESPAN will be influenced by several factors such as the number of discharging and recharging cycles and the ambient temperature It is...

Страница 14: ...o confirm the rating of EPS Flashing Rapid Beep 30s Battery missing in Line Mode Turn the EPS off Check battery wiring and the presence of the battery NO IMAGE Rapid Beep Overheat Over 70 158 Check fa...

Страница 15: ...ility Mode No Output Voltage EPS connected devices short circuit Output voltage detector broke down Input relay broke down E22 Output Overload Too many connected devices Output voltage detector broke...

Страница 16: ...Do not dispose of battery in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries Lead acid batteries should be recycled CAUTION Do not open or mutilate the batt...

Страница 17: ...act CyberPower Systems or local agent about replacement batteries The EPS cannot be turned on The on off switch is designed to prevent the damage that rapidly turns it off and on Turn the EPS off Wait...

Страница 18: ...lity Circuit Breaker On Battery Internal Current Limiter Transfer Time 10 ms Typical Output Receptacles UK Schuko France Type 2 Terminal Block External Battery Voltage x Recommended Rating X Quantity...

Страница 19: ...er Systems Inc For more information contact us at CyberPower Systems Inc Website www cpsww com Entire contents copyright 2014 CyberPower Systems Inc All rights reserved Reproduction in whole or in par...

Отзывы: