FAULT WARNING DISPLAY AND ALARM
Fault warning display and alarm
1.
The following table shows each corresponding warning message on the LCD display and the alarm
reacts during the machine shutdown:
LCD Warning
Display
Alarm
Condition
Solution
Long Beep
Overload
Check total load to
confirm the rating of
EPS.
(Flashing)
Rapid Beep
(30s)
Battery missing in Line Mode
Turn the EPS off. Check
battery wiring and the
presence of the battery.
NO IMAGE
Rapid Beep
Overheat (Over 70
℃
/158
℉
)
Check fans function and
air vent clearances.
Rapid Beep
Low Battery. Battery Capacity
shows 0% in General Mode.
Recharge the battery.
Rapid Beep
Overcharge in Line Mode
Inform service agents.
After warning, all above except
“Battery missing in Line Mode” will all shut down. For “Battery
missing in Line Mode