SAFETY AND EMC INSTRUCTIONS

 

                           

 

Safety and EMC instructions 

This manual contains important safety instructions. Please read and follow all instructions carefully during 

installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or 

operate your Emergency Power System (EPS). 

 

CAUTION!

    To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity 

controlled  indoor  area  free  of  conductive  contaminants.  (Please  see  specifications  for  acceptable 

temperature and humidity range). 

 

CAUTION!

    To reduce the risk of electric shock, do not remove the cover. 

   

CAUTION!

    EPS  must  be  connected  to  an  AC  power  outlet  with  circuit  breaker  protection.  Do  not 

plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the 

unit. 

 

CAUTION!

    To avoid electrical shock, turn off the unit and unplug it from the AC power source before 

servicing EPS, replacing the external battery or installing equipment. 

 

CAUTION!

   

To  reduce  the  risk  of  fire,  only  connect  the  EPS  to  a  circuit  with  16  amperes 

(

CPS1500PIE

 

Series

)  maximum  branch  circuit  over-current  protection  in  accordance  with  the  CE 

requirement. 

CPS1500PIE Series include CPS1500PIE, CPS1500PIE-FR, CPS1500PIE-UK and other versions. 

 

CAUTION!

   

The  building  wiring  socket  outlet  (shockproof  socket  outlet)  must  be  easily  accessible 

and close to the EPS. 

CAUTION!

   

Please  use  only  VDE-tested,  CE-marked  mains  cable  (e.g.  the  mains  cable  of  your 

equipment) to connect the EPS to the building wiring socket outlet (shockproof socket outlet). 

CAUTION!

   

Please use only VDE-tested, CE-marked power cables to connect the loads to the EPS. 

CAUTION!

   

When installing the equipment, ensure that the sum of the leakage current of the  EPS 

and the connected equipment does not exceed 3.5mA. 

CAUTION!

   

This  is  permanently  connected  equipment  and  only  qualified  maintenance  personnel 

may carry out installations. 

CAUTION!

   

Do  not  disconnect  the  mains  cable  on  the  EPS  or  the  building  wiring  socket  outlet 

(shockproof socket outlet) during operations since this would  remove the protective  ground of the EPS 

and of all connected loads. 

 

CAUTION!

   

The EPS shall be connected to the emergency switching device. 

Содержание CPS1500PIE

Страница 1: ...User s Manual CPS1500PIE K01 0000133 03 EN CyberPower Systems Inc Website www cpsww com...

Страница 2: ...equipment CAUTION To reduce the risk of fire only connect the EPS to a circuit with 16 amperes CPS1500PIE Series maximum branch circuit over current protection in accordance with the CE requirement C...

Страница 3: ...emands of these devices will overload and possibly damage the unit DO NOT INSTALL THE EPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR HEAT DO NOT BLOCK OFF VENTILATION OPENINGS IN THE EPS S H...

Страница 4: ...the ON and OFF positions 2 DO NOT plug a laser printer paper shredder copier space heater vacuum or other large electrical device into the EPS The power demand of these devices may overload and damag...

Страница 5: ...put of 1b is 12A for UK socket 16A for Schuko France socket Max Output wattage of 1a 1b is 1050W Note Maximum cord length is 10 meters and the cable O D must be 14AWG 2 AC Inlet AC input terminals Not...

Страница 6: ...Output Selector The unit has specific Bypass function Bypass The switch provides the bypass for charge only and shutdown the unit when the utility power exceeds 300Vac or below 140Vac In charger only...

Страница 7: ...ssionals 1 Remove the cover from the back of the machine 2 Make sure the POWER SW Output Selector and the BATTERY SW are turned off Step1 3 Connect the AC OUTPUT connections AC plugs or terminal conne...

Страница 8: ...isplay toggle Selected Switch once The output voltage showing on the LCD Module Display should be 220V This completes the start up process Step 6 9 Press and hold the Display toggle switch for 4 secon...

Страница 9: ...on When a severe brownout or blackout occurs this icon illuminates and an alarm sounds 2 short beeps followed by a pause to indicate the EPS is operating from its external batteries During a prolonged...

Страница 10: ...2 Set up Mode Step 1 The machine enters Set up Mode after the Display Toggle is pressed and held for 10 seconds When icons 1 2 see page 8 all illuminate the EPS is in the Set up mode Step 2 By pressin...

Страница 11: ...tage supplied in the area country where the EPS will be used Default 220V Choice 220 230 240V e Static Frequency Tolerance The settings may be adjusted to the quality of the electricity in use Default...

Страница 12: ...ont panel for 10 seconds and let the EPS enter Set up Mode Step 2 By pressing the Display Toggle switch setup function to Battery Capacity Charging Current Step 3 Press and hold the toggle for 4 secon...

Страница 13: ...more information please contact the local agent CAUTION BATTERY LIFESPAN will be influenced by several factors such as the number of discharging and recharging cycles and the ambient temperature It is...

Страница 14: ...o confirm the rating of EPS Flashing Rapid Beep 30s Battery missing in Line Mode Turn the EPS off Check battery wiring and the presence of the battery NO IMAGE Rapid Beep Overheat Over 70 158 Check fa...

Страница 15: ...ility Mode No Output Voltage EPS connected devices short circuit Output voltage detector broke down Input relay broke down E22 Output Overload Too many connected devices Output voltage detector broke...

Страница 16: ...Do not dispose of battery in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries Lead acid batteries should be recycled CAUTION Do not open or mutilate the batt...

Страница 17: ...act CyberPower Systems or local agent about replacement batteries The EPS cannot be turned on The on off switch is designed to prevent the damage that rapidly turns it off and on Turn the EPS off Wait...

Страница 18: ...lity Circuit Breaker On Battery Internal Current Limiter Transfer Time 10 ms Typical Output Receptacles UK Schuko France Type 2 Terminal Block External Battery Voltage x Recommended Rating X Quantity...

Страница 19: ...er Systems Inc For more information contact us at CyberPower Systems Inc Website www cpsww com Entire contents copyright 2014 CyberPower Systems Inc All rights reserved Reproduction in whole or in par...

Отзывы: