22
CYB-KLED CyberSuite Installation Manual
Panic Options ([MENU] , [2] , [4])
The panic options set functions that relate to the panic processing of
the CyberSuite system.
To enter the Panic Options Menu, press
[MENU] , [2] , [4]
To toggle options press the keys [1] to [8] , and the corresponding
Zone LED will be lit when that option is ENABLED.
Pressing the [ENTER] key will save the options.
Option 1 - 1+3 Silent Panic
5
Enabled the system will send a silent panic alarm to
the front desk when the 1+3 keys are held for a
period of 2 seconds. No message will be displayed on
the screen or alarm generated.
6
Disabled the 1+3 will not cause any alarm.
Option 2 - 4+6 Medical Alarm
5
Enabled the system will send a medical panic alarm to
the front desk when the 4+6 keys are held for a
period of 2 seconds. No message will be displayed on
the screen or alarm generated.
6
Disabled the 4+6 keys will not cause any alarm.
Option 3 - 7+9 Fire Alarm
5
Enabled the system will generate a local fire alarm on
the CyberSuite keypad and also alert the central
station and on site monitoring.
6
Disabled the 7+9 keys will not cause any alarm.