16
CYB-KLED CyberSuite Installation Manual
Reader Pre-Alarm Timer ([MENU] , [1] , [4])
The Reader Pre-Alarm Timer is programmable from 0 to 255 seconds
(Default 30 Seconds). This is only used when the Reader Slave
Network is enabled.
To program the timer value, press
[MENU] , [1] , [4] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER]
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9
number keys.
The minimum Pre-Alarm Time is 5 seconds, any number lower than 5
seconds entered will be automatically increased to 5 seconds to
ensure correct reader operation.
Reader Left Open Timer ([MENU] , [1] , [5])
The Reader Left Open Timer is programmable from 0 to 255 seconds
(Default 45 Seconds). This is only used when the Reader Slave
Network is enabled.
To program the timer value, press
[MENU] , [1] , [5] , [TIM 1], [TIM 2] , [TIM 3] , [ENTER]
Where TIM 1 ~ 3 are the timer value digits, entered using the 0 to 9
number keys.
The minimum Left Open Time is 5 seconds, any number lower than 5
seconds entered will be automatically increased to 5 seconds to
ensure correct reader operation.