This function allows the calibration of the touch screen.
S
ETTING
I
NSTRUCTIONS
:
Simply follow the instructions on the page to calibrate the touchscreen.
Use your finger or the plastic tip of a pen to calibrate the Touchscreen. Never use
sharp objects as this will damage the screen.
When this parameter is set to
yes
When this parameter is set to
yes
, the button up
is available when the beam is not at
TDC.
Upward command
The beam goes up as long as the button is pressed.
Go to TDC max
The beam goes to TDC max
Go to next TDC
The beam goes to the next TDC. (first to programmed TDC, then
to the TDC max)
This function allows choosing the data entry mode for the back gauge on the
EasyBend Page
. When set to
yes
, the length of the flange icon
is
displayed by default. When set to no, the icon for the position in mm of the back gauge
is displayed.
When set to
never
, the position of the back gauge is no longer linked to the bending
angle, i.e. the position is never recalculated when the bending angle is modified.
The default value for this preference is
never
. Note that completely formatting
the machine will reset this preference to its default value.
The
mode is not available for graphical parts (see also
gauge (X axis) / flange length
When this parameter is set to
yes
, the down movement of the beam is stopped and the
beam is maintained in closed loop at pinch point during the retraction. The beam cycle will
resume as soon as the back gauge has finished its retraction.
Touchscreen
Calibration
Offset Pinch Point
function
Show button up
Beam stop during
retractation