Cyan Z-Series Engineering and Planning Guide
Release 5.0
700-0023-05-00 Rev. 1
© 2013 Cyan, Inc. – All Rights Reserved.
P a g e
85
2.6.1 System Requirements
Cyan Z77, software version Release 5.0 or higher
2.6.2 Ethernet Services and Standards
•
MEF EPL, EVPL and E-LAN services with local bridging between UNI-N and NNI port
•
VLANs (IEEE 802.1Q)
•
Q-in-Q (IEEE 802.1ad)
•
MAC bridging (IEEE 802.1D)
•
2,000 TESIs
•
Connection oriented Ethernet (COE) support:
Provider Backbone Bridging - IEEE 802.1ah
Provider Backbone Bridging (Traffic Engineering) - IEEE 802.1Qay
•
Ethernet Ring Protection ITU-T G.8032v2 with sub-50ms switch times
•
Spanning tree (IEEE 802.1D), multiple spanning tree (IEEE 802.1s), and Rapid Spanning Tree
(IEEE 802.1w) support (planned for a future release)
•
P-bit priority QoS (IEEE 802.1p)
•
8 class of service queues per port
2.6.3 Optical Transport
•
4 x 10 GbE XFP, plus 6 x 10 GbE SFP+
•
All ports support optional OTU2
•
ITU-T G.975 Generic Forward Error Correction (GFEC) and Enhanced Forward Error Correction
(EFEC)
2.6.4 Interfaces
•
10 x 10 GbE LAN/WAN
•
Physical: Front access, XFP and SFP+
2.6.5 Management
•
ITU-T G.709 and OTN support on all DWDM interfaces
•
SNMP v2
•
CLI and TL1
•
A – Z circuit provisioning using Planet Operate (TESI provisioning only in this Release)
2.6.6 Physical
•
Module dimensions:
Depth: 11.6" / 295 mm
Width: 1.2" / 30.5 mm
Height: 13.8" / 350 mm
•
Weight: 4.0 lbs / 1.8 kg