![Cyan L-AMP Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/cyan/l-amp/l-amp_engineering-and-planning-manual_2701312006.webp)
Cyan Z-Series Engineering and Planning Guide
Release 5.0
P a g e
6
© 2013 Cyan, Inc. – All Rights Reserved.
700-0023-05-00 Rev. 1
Warning
Operating I-Temp equipment in an area that exceeds ambient air temperature of 65° C /
149° F will result in overheating.
Warning
Ultimate disposal of this product should be handled according to all national laws and
regulations.
Warning
Connect the unit only to DC power source that complies with the safety extra-low voltage
(SELV) requirements in IEC 60950-based safety standards.
Warning
This is a Class A product. In a domestic environment this product may cause radio
interference, in which case the user may be required to take adequate measures.
Warning
This is a Class A product based on the standard of the VCCI Council. If this equipment is
used in a domestic environment, radio interference may occur, in which case, the user may
be required to take corrective actions.
Warning
This equipment is a class A product and should be used and installed properly according to
the Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for
typical commercial establishments for which special conditions of installation and
protection distance are used.
Warning
This is a Class A Information Product. When used in residential environment, it may cause
radio frequency interference, under such circumstances, the user may be requested to take
appropriate countermeasures.
Warning
This is a Class A Device and is registered for EMC requirements for industrial use. The seller
or buyer should be aware of this. If this type was sold or purchased by mistake, it should be
replaced with a residential-use type.
Warning
Air Management Boards are required to meet EMI certification standards. Air Management
Boards must be installed to cover all unused slots.
Caution
Environment requires a moderate level of awareness. There is a moderate level of danger to
yourself or others.
Caution
To avoid damage to the Z22 shelf, the fan module should not be removed for longer than 60
seconds from an operating system.
Caution
Keep all ventilation openings clear and unobstructed.
Caution
To prevent damage, do NOT install or remove XFP/SFP transceivers with cables attached.
Caution
The Air Management Boards are essential to proper cooling of the shelf assembly. Air
Management Boards must be installed over all unused slot openings to prevent damage
from overheating.
Caution
Do not apply power to the unit until you complete all installation steps and check the
continuity of the battery and battery return. When terminating power, return, and frame
ground, do not use soldering lug connectors, push-in connectors, quick-connect
connectors, or other friction-fit connectors.
Caution
Star washers must be used for anti-rotation on all power and ground fasteners.
Caution
Use copper conductors only.