The graphic below shows the block diagram for the Z-Series FLX-216i module.
A total of eight (8) client ports, numbered 3 through 10, are supported by a 10G OTN mapper in the
FLX-216i module and another eight client ports, numbered 11 through 18, are supported by a separate 10G
OTN mapper. Although you can configure any combination of supported signal types in either set of eight
client ports, the total data rate for each set (after mapping into ODU0, 1.25G, and ODU1, 2.5G) cannot
exceed 10G. For example, a 10G OTN mapper supports eight ODU0 or four ODU1 client signals.
Note: The block diagram above reflects support for card-to-card traffic, which is not supported in
Release 4.3 and 5.0. The FLX-216i module in Release 4.3 and 5.0 supports single-card muxing.
Support for card-to-card traffic is planned for a future Release.
2.15.1 System Requirements
•
Cyan Z22 (-48V shelf) software Release 4.3 or higher
•