Operating instructions Screw compressor SKL 1200 C
Maintenance
26
ATTENTION!
Use only specified oil. Refer to rating plate oil on
the compressor or chapter 3 Tab. 4 and Tab. 5:
Types of gear oil.
WARNING!
Risk of burns from hot oil!
Hot oil can cause serious personal injury.
Therefore:
Allow the gear oil to cool down before checking
the oil level.
Change gear oil
•
Open the oil drain screw (5) at the lowest point,
drain oil.
•
Dismantle oil filter with the aid of a strap wrench. Lightly oil the
new oil filter on the rubber seal and tighten by hand.
•
Close oil drain screws, fill in oil (see section 3 Tab. 4 and Tab.
5) as described above and check filling level.
WARNING!
Risk of burns from hot oil!
Hot oil can cause serious personal injury.
Therefore:
Allow the gear oil to cool before changing.
Safety valve inspection
The safety valve must be secured against misadjustment.
Functional testing is carried out by actuating the manual ventilation
with the compressor running.
Measures to be taken in the event
of prolonged standstill
During a lengthier standstill, we recommend to put the compressor
into operation once a week for approx. 15 minutes.