Page 3 of 58
Description of FR-850 Design
This appliance is supplied as a complete suite of gas fire burner unit, enclosure
and fascia. To comply with the approval this fire must be installed as designed.
There are two versions which can be purchased by the customer depending on
site specific conditions like chimney size and room ventilation. Read this booklet
carefully and check the delivery paperwork and data plate inside the fire to
confirm which version is to be installed.
The versions are:
•
RIBBON (FR-850) –
(Natural Gas or LPG)
This version has a minimum
flue requirement of 178mm diameter or Class 1 chimney at 2m in length.
This version needs room ventilation with a 100cm2 air vent to the outside
air.
•
RIBBON (FR-850-NV) –
(Natural Gas Only)
This version has a minimum
flue size of 127mm diameter flue or Class 2 chimney at 3m in length. This
version does not need room ventilation. The enclosure on this version
features a glass panel to reduce the opening. This glass panel must be fitted
at the factory at time of order. This version of the fire must not be operated
without the glass panel fitted.
If the fire has been delivered to site as FR850-NV with the glass
panel then the fire must never be operated without the glass in
place. Refer to the Data Plate. If the glass is damaged a
replacement must be purchased from the manufacturer.