Check the Flue System
•
Turn the appliance to the maximum setting. Leave the appliance for 10
minutes and then test that all the products of combustion are entering
the flue by traversing the perimeter of the fireplace opening or canopy
using a smoke generator e.g. smoke matches. If the appliance passes
this test then it can be signed off. If the test is failed leave the fire for a
further 10 minutes and test again. If it still fails, disconnect the gas and
do not use the appliance until the chimney has been rectified.
Complete the Installation
•
The customer should be shown in detail how to operate the appliance and
the installation and user manual given to the customer.
•
The customer must also be made aware that
the appliance must be
serviced every 12 months
and that chimney or flue system should be
checked regularly to ensure the appliance operates at optimum
performance.
•
The customer must be told not to block the air vent (FR-850-V only)
•
The warranty card is to be completed by the registered engineer who has
commissioned the appliance. This is to validate the warranty. The card
must then be given to the customer for postage back to the factory.
FINAL SAFETY CHECK
•
Is the inlet pressure within the 21mBar to 19mBar limits when
the fire is operating on full?
•
Is the flue/chimney operating safely?
•
Are the flue/chimney and enclosure sealed?
•
Are all gas inlet holes in the burner tray sealed with metal tape?
•
Are all the heat shields fitted?
•
Is there room ventilation (FR-850-V-V)?
•
Has the customer being shown how to operate the appliance, and
how to use the handset?
•
Has the customer been shown how to replace the batteries in the
handset and main appliance?
•
Has the commissioning sheet on page 31 been completed?
•
Give the install booklet to the customer.
•
Give the warranty card to the customer.
If you have any questions, or the gas fire is not operating correctly, contact the
manufacturer on 01325-327221 before you leave the installation.
If the appliance is not fitted in strict accordance with these instructions, Spirit
Fires cannot be held responsible for any damage caused and reserve the right
to charge for any corrective work.