7.5 WLAN
The menu item WLAN can only be selected if a WLAN card was
recognized at switching on the printer.
For more information, please see the separate manual.
7.6 Scanner
7.6.1 COM2
Off:
serial interface Off
On (mode 1):
serial interface On
On (mode 2):
serial interface On; no error message appears in case
of a transmission error
Indication of bits which are transferred per second (speed of data
transfer).
Value range: 1200, 2400, 4800, 9600, 19200, 38400, 57600 and
115200.
None:
No parity
Even:
Even parity
Odd:
Odd parity
Setting of data bits.
Value range: 7 or 8 Bits.
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
7.6.2 General Parameters
Mode 0
= Off
Mode 1
= Compare data
Bar code date which was read by the scanner is compared with the
printed data.
Mode 2
= Check readability
It is only checked if the scanner can read the printed bar codes.
Mode 3
= Chech readability graphic
It is only checked if the scanner can read the printed bar codes. This
mode is to use if the bar code is available as graphic (e.g. printing with
printer driver). In this case the printer cannot recognize that a bar
code is placed onto the label.
COM2 Mode
Baud rate
Parity
Data bits
Stop bits
Operating mode