Options
Spectra II
62
Operating Manual
08.17
1
Print start and cut (Input)
2
Reprint last printed label (Input)
3
Counter reset (Input)
4
Option applicator only:
Start application (Input)
5
Error reset (Input)
6
Cancel all print jobs (Input)
7
No function
8
No function
9
Error (Output)
10
Print order active (Output)
11
Dispenser photocell:
Label exists at dispenser photocell (Output)
12
Printing (Output)
13
Ready (Output)
14
Option applicator only:
Ready for application (Output)
15
Option applicator only:
Pad is in printing position (Output)
16
Transfer ribbon prior warning (Output)
Indication of debounce time of the dispenser input. The setting range
of the debounce time is between 0 and 100 ms.
In case the start signal is not clear then you can debounce the input
by means of this menu item.
Indication in time per second of the delay for the start signal.
Value range: 0.00 … 9.99.
On:
The start signal for the next label can already be released during
printing the current label. The signal is registered from the printing
system. The printing system starts printing the next label immediately
after finishing the current one. Therefore time can be saved and
performance be increased.
Off:
The start signal for the next label can only be released if the
current label is printed to the end and the printing system is again in
'waiting' state (output 'ready' set). If the start signal was released
already before, so this is ignored.
Indication of interface at which the modifications of input signals (I/O)
are sent.
For special applications, an extended dispenser edge can be used.
With the external synchronization and the connexion of an external
label sensor at the dispensing position of the label (see I/O ports), the
accuracy of label positioning at the dispenser edge can be improved.
List of registered
functions for APL
Debounce
Start delay
Save signal
I/O protocol port
External
synchronization