Spectra II
Function Menu
08.17
Operating Manual
39
Selection of the used photocell.
The selection of one of the following photocell types is possible:
transmission photocell normal and inverse, reflexion photocell normal
and inverse, ultrasonic photocell (option)
(see chapter 11.4, page 112).
Entry of percental label length by that the label end is searched.
Marks onto the label can be skipped.
If no new label can be recognized, indication after how many mm a
message appears in the display.
On:
If no new label is recognized, it is not printed. The new data
remains in the memory.
Off:
Although no new label is recognized, the next data is printed and
removed from the memory.
6.2.3 General Parameters
Indication of label length in mm.
Indication of distance between two labels in mm
(not for continuous labels).
Indication of label width in mm.
Press key
to start the measuring process. The printer stops
automatically after termination of measuring. The determined values
are displayed and saved.
6.3 Device Settings
6.3.1 Print Job
Off:
The complete print memory is deleted.
Keep graphic:
A graphic res. a TrueType font is transferred to the
printer once and stored in the printer internal memory. For the
following print order only the modified data is transferred to the printer.
The advantage is the saving of transmitting time for the graphic data.
The graphic data created by the printer itself (internal fonts, bar codes,
...) is generated only if they were changed. The generating time is
saved.
Delete graphic:
The graphics res. TrueType fonts stored in the
printer-internal memory is deleted but the other fields are kept.
Photocell
Label synchronization
position
Error length
Synchronization
Label length
Gap length
Label width
Measure label
Field handling