![CUTES CT-2000F Series Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/cutes/ct-2000f-series/ct-2000f-series_instruction_2701009047.webp)
C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG 02413.281.181-0989.984.666
Website:www.viet-trung.com.vn Đ/c:194-Nguyễn Trãi-Võ Cường-TP.Bắc Ninh
47
Adjust and Function Specification
§
Cd31 Initial factory setting (Settable range 0,1)
The function cannot be modified during revolution.
Set data to original factory setting.
Cd31=0 No change
Cd31=1 Initial factory setting, refer to function code table.
Note:
After this function is active, content value returns to “0”, readable value
is always “0”.
§
Cd34 Dead Time compensation delay angle
(
Settable range 0~80
)
Default setting. Can’t be adjustable
Adjust angle of DEATIME compensation in accordance with current feedback
waveform.
§
Cd36 Failure record clear (Settable range 0, 1)
Clear the failure record content of Code 32, 33, 34, and 35.
Cd36=0 No change
Cd36=1 All of the contents of data will be “nOnE”, display of “LoAd” after setting
Note: After this function is active, content value automatically returns to “0”, thus
readable value is always “0”.
§
Cd37 Frequency gain setting (Settable range 20-200)
Select ratio of frequency gain
Gain setting for external input signals are available using this function.
Output Frequency = Set Value
×
Frequency Gain
×
MAX. frequency
Ex. Under the mode of external voltage (0-10V) frequency setting,
frequency gain = 100%, set voltage to 2V,MAX. frequency (FH) is 120Hz:
Output Frequency = (2V/10V)
×
120Hz
×
100% = 24Hz
If change frequency gain to 150%, then
Output Frequency = (2V/10V)
×
120Hz
×
150% = 36Hz