![CUTES CT-2000F Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/cutes/ct-2000f-series/ct-2000f-series_instruction_2701009035.webp)
C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG 02413.281.181-0989.984.666
Website:www.viet-trung.com.vn Đ/c:194-Nguyễn Trãi-Võ Cường-TP.Bắc Ninh
35
O
u
tp
u
t
V
o
lt
a
g
e
V
B
Adjust and Function Specification
§
Cd07 Torque compensation Vb (Settable range 0-150)
The function cannot be modified during revolution.
This function is to raise output voltage to increase torque of motor.
It can also be used to increase load slope of low voltage produced by long wiring
between inverter and motor, as well as fluid, fan and pump.
100%
50%
15%
FS
0%
Output Frequency (HZ)
§
Cd08, 09, 10, 11 Acceleration / deceleration time (Settable range 0.1-6000)
The time needed for set frequency from 0Hz to 50Hz.
There are 2 selections for each of acceleration time and deceleration time.
To set acceleration/deceleration time
Set Value (T) = (50 - 0) /
△
F
×
T1
T1: time needed for accelerate / decelerate
△
F: frequency changed
Ex.: Frequency from 50Hz down to 30Hz, needed time 1 sec. Then:
Set Value (T) = 50 / 50 - 30
×
1 = 2.5
Cd08 = Acceleration time
Cd09 = Deceleration time
Cd10 = 2
nd
Acceleration time
Cd11 = 2
nd
Deceleration time
Note: The 2
nd
acceleration / deceleration time only available on external
operation mode. (e.g. Cd04=1)
§
Cd12, 13, 14 Speed setting (Settable range 0.5-240)
This function has 4 kinds of speed setting
The 2
nd
, 3
rd
, 4
th
speeds are set from external terminal FR (or RR) which accommodate
terminal 3, 5, the setting value cannot exceed the allowed range.
Cd12 = 2
nd
speed setting