4 Multi-role Recorders User Guide (HW/BK/0034 | 12 Oct. 2021)
2
Multi-role recorder connectors
This section describes connecting typical devices to a multi-role recorder. The following figure shows the
connectors on an SSR/CHS/001/B multi-role recorder.
Figure 1: SSR/CHS/001/B interfaces
N
OTE
:
We recommend that Category 5 (or better) UTP Ethernet cables as specified in Ethernet cabling standard
(TIA/EIA-568-B.2-2001) are used for 100BaseTX and 1000BaseT connections.
W
ARNING
:
The use of third party mating connectors may result in damage to the mating connector and to the con
-
nector on the multi-role recorder. Such damage would incur out of warranty repair costs.
Connecting the 6-way power interface to a power supply
Use the supplied CON/PSU/007 to connect the power interface to a 28V DC power supply.
1.
Assemble the CON/PSU/007 connector.
See the
CON/PSU/007
data sheet.
2.
Connect the CON/PSU/007 to the 6-way power interface on the multi-role recorder.
3.
Connect the other end to the aircraft DC power supply.
Connecting the 10-way Ethernet interface to a PC
Use the supplied NET/CON/017 cable to connect the multi-role recorder to a PC.
1.
Using the NET/CON/017, connect the CON/MMO/001/F10A cable end to the 10-way Ethernet connector on
the multi-role recorder.
2.
Connect the RJ45 cable end to a network interface card on a PC.
1
2
3
4
19-way (Mighty Mouse)
connector
10-way (Mighty Mouse)
Ethernet connector
Ground mounting
bolt
GPS
Voice connector
6-way power
connector
Содержание SSR/CHS/001/B
Страница 1: ...May 27 11 28 15 Logging Multi role Recorders User Guide ...
Страница 2: ......
Страница 32: ...This page is intentionally blank ...