Curtiss-Wright
Parvus DuraDBH-672
Quick Start Procedure
MNL-0661-01 Rev A1
ECO-N/A
Effective: 25 January 2016
Page 17 of 34
Q
UICK
S
TART
P
ROCEDURE
This chapter describes how to connect and power-up the DuraDBH-672.
T
EST
E
QUIPMENT
To use the DuraDBH-672 in a lab environment, recommended equipment includes:
Appropriate cables, such as the CBL-DBH672-4B starter breakout cable set or custom cables
A power source applied at connector J1, 9-36VDC input, 28V nominal. A power cable is included
with the Breakout Cable Set.
A host PC with a free RS-232 port and/or an Ethernet port
28VDC
Figure 4. Connection the DuraDBH-672
P
OWER
‐
ON
S
EQUENCE
To configure the DuraDBH, you need a serial or Ethernet connection to a host PC. These instructions
cover both types of connections.
Follow these steps:
1. Connect the cable set to the DuraDBH-672
2. Connect the other end of the power cable to the
unpowered
DC power source.
Caution! Make sure that the DC power source is set to provide 9 to 36VDC (28V nominal).