User Guide
DDOC0099-000-AH
DTS1 CSfC
9 - 2
Troubleshooting
© 2020 Curtiss-Wright Defense Solutions
Revision 0.0
9.3
Encryptor Error Codes
NOTE
If problems persist, contact Curtiss-Wright Defense Solutions Customer Support. Refer to
for contact information.
Refer to Table 9.3 for fault information.RMC module
Table 9.2
RMC Module LED Fault Indications
Symptoms/Condition
Meaning
Investigative/Remedial Action
RMC module red Fault LED on. Self-test failed
1. Run
CLI command. If the problem can
be associated with the RMC module, run
2. Reseat
RMC module and cycle power.
Cannot store data.
RMC module may be full.
Run
CLI command.
No access to RMC module.
Cannot login to RMC module.
Encryptor battery dead. Replace battery. Refer to
for detailed instructions.
Table 9.3
Encryptor Error Codes
Symptoms/Condition
Meaning
Investigative/Remedial Action
0x0103
AES
Memory allocation error
0x0109
AES
KAT (known answer test) failed
0x0203
KEY_WRAP
Memory allocation error
0x0209
KEY_WRAP
KAT (known answer test) failed
0x0210
KEY_WRAP
Initialization vector error
0x0303
SHA
Memory allocation error
0x0309
SHA
KAT (known answer test) failed
0x0403
HMAC
Memory allocation error
0x0409
HMAC
KAT (known answer test) failed
0x0503
DRBG
Memory allocation error
0x0509
DRBG
KAT (known answer test) failed
0x0603
RNG
Memory allocation error
0x0609
RNG
KAT (known answer test) or continual test failed
0x0720
encryptor
3.3Vpower supply error
0x0730
encryptor
2.5Vpower supply error
0x0740
encryptor
1.8Vpower supply error
0x0709
encryptor
KAT (known answer test) failed
0x0810
I2C
Interrupt handler error
0x0901
SATA_P_CTRL
Initialization error
0x0904
SATA_P_CTRL
Write error
0x0905
SATA_P_CTRL
Read error
0x0A10
ENCRYPTION
Chip_A BIST error
0x0A20
ENCRYPTION
Chip_B BIST error
0x0A30
ENCRYPTION
Chip_C BIST error