User Guide
DDOC0099-000-AH
DTS1 CSfC
A - 6
Specifications
© 2020 Curtiss-Wright Defense Solutions
Revision 3.0
Vibration, Operating
Sine............................................................... 4 G peak, 74-2k Hz sine wave (RTCA/D0-160D,
Curve T modified as indicated)
Random......................................................... 0.02 g2 /Hz from 5Hz to 2kHz (60 minutes per axis,
in each of three mutually perpendicular axes).
Shock, operating ........................................... 20 g's peak, 11 ms wide, 2kHz frequency range
-MIL-STD 810 Method 516.4, Procedure 1
-MIL-STD 810-half sine
-MIL-STD 810-Terminal Peak Sawtooth
-MIL-STD 810-Initial Peak Sawtooth
-MIL-STD 810-20 impacts per axis, total of 60
impacts.
A.6
EMI Compliance
The Curtiss-Wright Data Transport System (DTS) was evaluated with respect to MIL-STD-461F
electromagnetic interference (EMI) requirements. Testing was performed in accordance with the
Standard. The DTS1 has passed and therefore complies with all of the following EMI
requirements.
The equipment was evaluated with respect to the following MIL-STD-461F requirements.
•
CE101 - Conducted Emissions, Power Leads, 30 Hz to 10 kHz
•
CE102 - Conducted Emissions, Power Leads, 10 kHz to 10 MHz
•
RE101- Radiated Emissions, Magnetic Field, 30 Hz to 100 kHz
•
RE102 - Radiated Emissions, Electric Fields, 2 MHz to 18 GHz
•
CS101 - Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz
•
CS114 - Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 200 MHz, Curve 5
•
CS115 - Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation
•
CS116 - Conducted Susceptibility, Damped Sinusoid Transients, Cables and Power Leads, 10
kHz to 100 MHz
•
RS101 - Radiated Susceptibility, Magnetic Fields, 30 Hz to 100 kHz
•
RS103 - Radiated Susceptibility, Electric Fields, 2 MHz to 18 GHz, 200 Volts/meter
A.7
Electrical Power Compliance
The DTS1 is tested to and complies with the following MIL-STD-704F electrical power tests:
Normal, Aircraft Electrical Operation
•
LDC101 Load Measurements
•
LDC102 Steady State Limits for Voltage
•
LDC103 Voltage Distortion Spectrum
•
LDC104 Total Ripple
•
LDC105 Normal Voltage Transients
Transfer, Aircraft Electrical Operation
•
LDC201 Power Interrupt Abnormal, Aircraft Electrical Operation
•
LDC301 Abnormal Steady State Limits for Voltage
•
LDC302 Abnormal Voltage Transients (Overvoltage / Undervoltage)
Emergency, Aircraft Electrical Operation
•
LDC401 Emergency Limits for Voltage Starting, Aircraft Electrical Operation
•
LDC501 Starting Voltage Transients
Power Failure, Aircraft Electrical Operation
•
LDC601 Power Failure
•
LDC602 Polarity Reversal
Contact Curtiss-Wright to obtain a detailed test report.