Mar 2017
Page 59
© Penny & Giles Aerospace Ltd. No part of this work may be reproduced or distributed by any
means without prior permission in writing from the copyright owner.
DATA ACQUISITION FLIGHT RECORDER Type D51615-202-XXX or D51615-
202-XXX-090- with CCU Type D51616-XXXX and CAM Type D51623-XXXX
Installation and Operating Manual with Illustrated Parts
List
Commercial in Confidence
PIM434-I
This procedure may be performed on the download PC or on a
desktop PC on to which the recovered data has been copied.
It is assumed that a database with appropriate parameter
definitions and aircraft equipment configuration has been
defined.
(1) Invoke the Professional Ground Station (PGS) software
on the analysis PC by selecting the PGS desktop icon
with the mouse.
(2)
From the toolbar/drop down menu select the
'Fleet
Manager'
option.
(3)
From the Fleet Management window, highlight the
appropriate aircraft for download.
(4)
Click on the
'Download'
button and select the
'Crash
Recorder'
option.
(5)
Click on the
'Configuration'
button and ensure that the
default IP address of ‘
10.0.0.100
’ is specified. Click OK
to return to the download.
(6)
From the check box options presented within this
window, select the
'FDR'
Data to download either
'All'
or
'Last Only'
option. If Last Only option is selected
enter the duration required followed by the
'Flight data
Master'
,
'System Log Files'
and
'Keep Compressed
Files'
options.
(7)
Click on the
'Download'
button. Wait for the process to
complete as identified by the progress bars at the
bottom of the window.
(8)
On completion click
'OK'
then click on the
'Cancel'
button to return to the
'Fleet Management'
window.
(9)
The aircraft should remain highlighted, therefore click
on the
'Flights'
button to identify the list of downloads
performed for this aircraft. Highlight the appropriate
flight (which should be the last in the list of flights
available).
(10)
Click on the
'Plot'
button and select the appropriate
parameter group, if configured. If parameter display
groups have not been configured, click on the
'Select'
option and chose parameters from those presented for
display.
(10) As far as practicable ensure all parameters are active
and are in range.