User Guide
DDOC0108-000-A2
CNS4 CSfC
11 - 19
Command Line Interface
Revision 0.0
11.2.13
health
NOTE
The CNS4 typically does not have an Ethernet cable attached to GBE3 (ETH3).
Syntax
health [-h | --help | --version]
health [-A] [-S] [-F] [-N] [-O]
Description
The health command displays health information for the CNS unit. FSM-C status, system status
and network status can be displayed.
Options
-h, --help.............................. Print help message.
--version .............................. Print program version.
-A, --all................................. Display all CNS health information. (default)
-S, --system......................... Display system specific health information.
-F, --fsm............................... Display FSM-C specific health information.
-N, --network ....................... Display network specific health information.
-E, --en ................................ Display encryptor status.
-T, --tf................................... Display temperatures in fahrenheit.
Responses
SYSTEM .............................................. System Health.
[date] .................................................... Date <str> (Month/Date/Year).
[time] .................................................... Time <str> (Hour:Minute:Second).
[cns ver]................................................ CNS Firmware version <str> (ex. 3.1).
[firmware ver] ....................................... Micro Controller firmware version <str> (ex.1.0).
[power supply temp <int>] ................... CNS Power Supply Temp <int> (-128 to 127).
[main board temp <str> <int>] .............. CNS Main Board Temp <int> (1|2) <int> (-128 to 127).
[flash] ................................................... Flash Read/Write state <str> (ro, rw).
[boot Flash] .......................................... Hardware Read/Write switch state <str> (ro, rw).
[FSM EEPROM] ................................... Hardware Read/Write switch state <str> (ro, rw).
<status> .............................................. Status <enum> (OK, NA, ERR "<str>").
FSMX ................................................... [state] [id] [Temp] [5V pwr] [3V pwr] [FaultLED] [Status
LED] <status>.
[FSMX] ................................................. FSM-C unit in slot X (X=slot number).
[state] .................................................. <str> ( N/A ) or <int> <int> <int> <str> <str>.
[id] ........................................................ Unique id of FSM-C <int> (105).
[temp] ................................................... FSM-C temp <int> (-128 to 127).
[5V pwr]................................................ Reading of 5V sensor.
[3V pwr] ............................................... Reading of 3.3V sensor.
[faultLED] ............................................ <str> (ON, OFF).
[statusLED]........................................... <str> (ON, OFF).
<status> ............................................... Status <enum> (OK, NA, ERR "<str>").
ETH_X.................................................. [ip] [link] <status>.
ETH_X.................................................. Ethernet device X (X=device number).
[ip] ....................................................... IP address <str> (ex. 192.168.0.1).
[link]...................................................... Link status <str> (down, 1000Mb/s, 100Mb/s, 10Mb/s).
<status> ............................................... Status <enum> (OK, NA, ERR "<str>").
INVALID ............................................... <status>.
INVALID ............................................... Command parameter(s) invalid
.<status> ............................................. Status <str> (ERR "<str>").
ERROR ................................................ <status>.
ERROR ................................................ Command parameter(s) invalid.
<status> ............................................... Status <str> (ERR "<str>").