background image

9

Liquid Level Probe

Cleaning intervals for the probe are to be determined by the user or the service tech based on water condi-

tions.  The use of water filters, or the type of water filter that is being used can impact the service interval.  

Intervals can be from one month to several years, however, replacing rather than cleaning the probe is 

preferable.

WARNING:

 Disconnect electrical power before removing access panels.

CAUTION: 

This procedure involves working with hot water and hot surfaces.

1. Unplug the power cord and shut off the water line.
2. Remove the top cover of the unit.  Locate the top of the tank and 

remove the cover.

3. Drain the tank to a level about 3” below the tip of the probe.
4. Allow some time for the probe to cool before working on the brewer.
5. Clean the tip of the probe using a Scotch-BriteTM  scuff pad. 
6. If a residual white layer is still visible on the probe, remove the 

probe and soak it in vinegar or a scale removing chemical. Repeat 

this step until the white layer is removed.  

Filter Pouch Cleaner

You may use a filter pouch cleaner to easily clean both the brew cone and the pour pot.

1. Place a pouch cleaner into the brew cone. Place an empty pour pot centered beneath the brew cone..
2. Press the brew button to run a full brew cycle into the pour pot.
3. At the end of the brew cycle, discard the used filter cleaner pouch.
4. Allow the cleaner to soak in the pour pot for 10 minutes. If the cof-

fee deposits are very heavy, you may use a sponge brush to aid in 

cleaning. 

5. At this time, you can dump out the cleaner or you can reuse it to 

clean additional pour pots.

6. Return the empty pour pot to the brew deck and run another brew 

cycle to run hot water through the brew cone and into the pour pot. 

This will rinse the brew cone and the pour pot.

7. Empty the rinse water from the coffee server.

Содержание D60GT10

Страница 1: ...left to right and front to back located on a solid counter top Connect a water line from the water filter to the brewer NOTE A water filtration system must be used to help maintain trouble free operat...

Страница 2: ...he tank approximately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen Approximately 20 minutes are required to reach the set point temperature Contr...

Страница 3: ...ess display will now show the next feature During the actual brew cycle a 2 minute drip mode is added to the brew time The programmed water level compensates for back to back brewing Delta 3 to allow...

Страница 4: ...the C pulse setting Of course any of the A B or C settings may be used to suit your taste profile There are two additional settings D and E that allow you to manually set the ON TIME pulses and OFF T...

Страница 5: ...1 0 GPM 120V 9A WC 856 VALVE INLET 1 GPM 240V 10W 10 WC 5970 COVER BACK CTR WRAP ALPHA D60GT 11 WC 8591 CAPACITOR X2 USED ON ALL ADS MODELS 12 WC 29025 SPRAYHEAD PURPLE ADVANCE FLOW 13 WC 3518 LEG GL...

Страница 6: ...T HEATING 3 5KW 220V W JAM NUTS WASHERS 22 WC 523 THERMOSTAT MANUAL RESET 120 240 VAC 25A 220 F MAX 22A WC 522 THERMOSTAT HI LIMIT HEATER CONTROL DPST 277V 40A 23 WC 6289 HEATING TANK CMPLT 120V W HI...

Страница 7: ...7 ELECTRICAL SCHEMATIC...

Страница 8: ...g using the cleaning solution Brush inside the brew cone with cleaning solution 3 Scrub the sprayhead area with a cleaner soaked cloth 4 Rinse the sprayhead area with a water soaked cloth removing any...

Страница 9: ...riteTM scuff pad 6 If a residual white layer is still visible on the probe remove the probe and soak it in vinegar or a scale removing chemical Repeat this step until the white layer is removed Filter...

Страница 10: ...eaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for proper cleaning and r...

Отзывы: