18
Strap Counts and Strap Limits
To view current strap limits and counts, press
STRAP
on the main screen. The
STRAP-
SETTINGS
screen is displayed. Configuring the machine’s software features can impact the
screen’s appearance. Examples are shown below.
Note Processing Enabled Check and Ticket Processing Enabled
Strap limits may be set for denominations and documents in all operating modes, except for
MIXED
,
MIXED/FACE
or
MIXED/ORIENTATION
. A strap limit may be set for any piece
count.
Denominations and document types are itemized in the DENOM column. The TICKET row
refers to the ticket count and appears when the machine is set to count tickets only. The COUNT
and CHECK rows refer to the non-value piece count and appear while using
COUNT
mode
or
processing checks.
The UNIT column indicates the current strap count. The LIMIT column indicates the current
strap limit.
How to Set Strap Limits
To set a strap limit:
1.
Press
or
to scroll through the denominations and document types. Stop on the desired
document.
2.
Enter a strap limit by doing one of the following options:
•
Press
LIMIT
to scroll through the preset strap limits. There are seven preset strap limits:
10
,
25
,
40
,
50
,
75
,
100
and
infinite
(
INF
). Stop on the desired setting.
•
Use the numeric keypad to enter the strap limit or press
0
for
infinite
. To delete one
character from the right, press
.
3.
Do one of the following:
•
Press
ALL
to set all denominations and documents at this strap limit.
•
Press
or
to select to the next desired document and repeat step 2 to set the strap
limit.
4.
When configuration is complete, press
EXIT
to return to the main screen.