Part No. 4801-5307 Rev 2-15
Evolution 3000 and 3001
11 of 70
NOTE: In this manual, Reference
numbers refer to descriptions given in
text. These numbers do not appear
on display.
Mon 14 Jun 2007 5:00 p
(1) Vent Mode: Minimum (6) Growout Day: 40
(2) Room Temp: 71.4°
(7) Water Consumption
Target: 70.0°
1. 240 (10/hr)
(3) Outside: 77.0°
2. 280 (10/hr)
(4) Pressure: 0.00 wc (8) Feed Levels
Target: 0.04 wc 1. 11.2ft ( 60%)
(5) Humidity: 0%
2. 5.0ft ( 23%)
(9)
* Sensor 1: 71.6°
* Sensor 2: 71.2°
* Sensor 3: 71.4°
Sensor 4:---.-°
Sensor 5:---.-°
Sensor 6:---.-°
Sensor 7:---.-°
Sensor 8:---.-°
Sensor is enabled
* Sensor used in Room Temp Calculation
6. Viewing Navigator Status Screens
The following nine screens are available: Current Conditions, Target Conditions, Minimum Vent, Stage
Conditions, Historical Data, Back-Up Status, Alarm Status, Network Status, Program Setup. The Navigator
selects the desired status screen by pressing the up and down SELECT arrows. The first eight screens
display status information and various setup options. The last screen is the Program Screen. To change
program parameters the Program Setup Screen must be selected.
6.1
Current Conditions
The current environmental conditions of the building are shown here. Below is a table describing the
variables that can appear in the Current Conditions status screen.
The numbers in brackets e.g. (1) refer to the descriptions below the sample screen displays.
(1) Vent Mode –
Indicates the current ventilation mode: either Minimum, Natural, Power, Transition or
Tunnel.
(2) Room Temp –
The average temperature of the sensors for display.
Target –
Target Temperature.
(3) Outside (Temperature) –
The outside temperature as indicated by the outside sensor.
(4) Pressure –
The current atmospheric pressure internal to the building.
Target –
Target Pressure.
(5) Humidity –
The percent of water vapor of the air inside the building.
VENT MODE
Definition
Minimum
Heat stages or timer fans operating. None of the negative stages are on because of
temperature.
Natural
The main curtains are open.
Power
The curtains are up and there are negative fans on because of temperature.
Transition
The control is transitioning into tunnel ventilation from either power or natural
ventilation. The control is making the adjustments needed to go into tunnel.
Tunnel
The tunnel signal has been activated and the system has entered into tunnel.
(6) Growout Day
– The current day in the growout period. The Current Conditions LED on the Navigator
panel will blink if the growout day is later then the current date.
(7) Water Consumption –
Water consumed for the current day; The total for the day is listed first then the
units per hour is shown inside ( ). Two water meters may be monitored (Water Meter 1 & Meter
2).
(8) Feed Level –
The Feed level is shown in number of feet from the bottom first then the percentage of
feed remaining in the feed bin is shown inside ( ). Two feed bins may be monitored (Bin #1 & Bin
#2).
(9) Sensor 1 through 8 –
The current temperature read by each sensor.