Model SY-2650
Substance
US EPA
Avg. Influent
Avg. (Max)
Avg. (Min)
Standard 42
MCL
Concentration
Effluent Conc.
Reduction
Chlorine-Class I
—**
2.0 mg/L
0.05 mg/L
97.5%
Particulates (0.5–
—**
10,790,000 #/ml 450,000 #/ml
96.0%
<1m)-Class I
Standard 53
MTBE
0.015 mg/L
.0014mg/L
90%
(.0047mg/L)
(69%)
Cysts†
99.95%
572,664 #/ml
168 #/ml
99.97%
Reduction
(339 #/ml)
(99.96%)
Turbidity
0.5 NTU*
26 NTU
0.16 NTU
99.4%
(0.23 NTU)
(99.2%)
Lead (6.5 pH)
0.010 mg/L‡
0.15 mg/L
0.0015 mg/L
99.0%
(0.008 mg/L)
(95.0%)
Lead (8.5 pH)
0.010 mg/L‡
0.16 mg/L
0.001 mg/L
99.4%
(0.003 mg/L)
(98.1%)
Mercury (6.5 pH)
0.002 mg/L
0.0058 mg/L
0.0005 mg/L
91.4%
(0.0005 mg/L)
(91%)
Mercury (8.5 pH)
0.002 mg/L
0.0062 mg/L
0.00058 mg/L
90.6%
(0.0011 mg/L)
(82.2%)
Asbestos
7,000,000 F/L 27,025,000 F/L
0.225 F/L
99.9%
(0.225 F/L)
(99.9%)
Flow Rate=0.6 gpm (2.27 Lpm) Capacity=500 gallons (1893 L) or 6 months
*US EPA Maximum Contaminant Level
**No maximum contaminant level
†NSF test requirement of at least 50,000 3–4 micron particles per milliliter.
The 3–4 micron particle size is a surrogate particle for Cryptosporidium and Giardia cysts.
‡US EPA Action Level for Lead
Performance Data
Important Notice:
Read this performance data and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before
installing a water treatment system, you have your water supply tested to determine your actual water treatment needs.
6
Organic Chemicals Included by Surrogate Testing:
Chemical
US EPA
Influent
Chemical
Maximum
MCL
challenge
reduction
product water
mg/L (ppm)
concentration
1)
percent
concentration
mg/L (ppm)
mg/L (ppm)
alachlor
0.002
0.050
>98
0.001
atrazine
0.003
0.100
>97
0.003
benzene
0.005
0.081
>99
0.001
carbofuran
0.04
0.190
>99
0.001
carbon tetrachloride
0.005
0.078
98
0.0018
chlorobenzene
0.100
0.077
>99
0.001
chloropicrin
–
0.015
99
0.0002
2,4-D
0.070
0.110
98
0.0017
dibromochloropropane (DBCP)
0.0002
0.052
>99
0.00002
o-dichlorobenzene
0.600
0.080
>99
0.001
p-dichlorobenzene
0.075
0.040
>98
0.001
1,2-dichloroethane
0.005
0.088
95
4)
0.0048
1,1-dichloroethylene
0.007
0.083
>99
0.001
cis-1,2-dichloroethylene
0.070
0.170
>99
0.0005
trans-1,2-dichloroethylene
0.100
0.086
>99
0.001
1,2-dichloropropane
0.005
0.080
>99
0.001
cis-1,3-dichloropropylene
–
0.079
>99
0.001
dinoseb
0.007
0.170
99
0.0002
endrin
0.002
0.053
99
0.00059
ethylbenzene
0.700
0.088
>99
0.001
ethylene dibromide (EDB)
0.00005
0.044
>99
0.00002
haloacetonitriles (HAN):
bromochloroacetonitrile
–
0.0022
98
0.0005
dibromoacetonitrile
–
0.024
98
0.0006
dichloroacetonitrile
–
0.0096
98
0.0002
trichloroacetonitrile
–
0.0015
98
0.0003
haloketones (HK)
1,1-dichloro-2-propanone
–
0.0072
99
0.0001
1,1,1-trichloro-2-propanone
–
0.0082
96
0.0003
heptachlor
0.0004
0.08
>99
0.0004
heptachlor epoxide
0.0002
0.0107
98
0.0002
hexachlorobutadiene
–
0.044
>98
0.001
hexachlorocyclopentadiene
0.050
0.060
>99
0.000002
lindane
0.0002
0.055
>99
0.00001
methoxychlor
0.040
0.050
>99
0.0001
pentachlorophenol
0.001
0.096
>99
0.001
simazine
0.004
0.120
>97
0.004
styrene
0.100
0.150
>99
0.0005
1,1,2,2,-tetrachloroethane
–
0.081
>99
0.001
tetrachloroethylene
0.005
0.081
>99
0.001
toluene
1.0
0.078
>99
0.001
2,4,5-TP (silvex)
0.050
0.270
99
0.0016
tribromoacetic acid
–
0.042
>98
0.001
1,2,4-trichlorobenzene
0.070
0.160
>99
0.0005
1,1,1-trichloroethane
0.200
0.084
95
0.0046
1,1,2-trichloroethane
0.005
0.150
>99
0.0005
trichloroethylene
0.005
0.180
>99
0.0010
trihalomethanes (includes):
chloroform (surrogate chemical)
0.080
0.300
95
0.015
bromoform
bromodichloromethane
chlorodibromomethane
xylenes (total)
10.0
0.070
>99
0.001
Technical Support: 1-800-645-5426, Monday-Friday, 7:30 am–5:00 pm, CST
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: May 17, 2000
Date Revised: March 9, 2001
1437
00 -
Trademark/Model Designation
Replacement Element(s)
Culligan SY-2300
D-250A
Culligan SY-2300S
D-250A
Culligan SY-2650
D-250A
Cysts (protozoan)
Turbidity
Asbestos
Lead
Mercury
MTBE
VOCs
Culligan
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Alachlor
Bromodichloromethane
1
Carbon Tetrachloride
2,4-D
o-Dichlorobenzene
1,2-Dichloroethane
cis-1,2-Dichloroethylene
Dinoseb
Ethylbenzene
Hexachlorocyclopentadiene
Methoxychlor
Styrene
1,1,2,2-Tetrachloroethane
1,1,1-Trichloroethane
m-Xylene
1
Trihalomethanes
Benzene
Carbofuran
Chloroform
1
Chlorodibromomethane
1
1,1-Dichloroethylene
cis-1,3-Dichloropropylene
Endrin
Heptachlor Epoxide
Lindane
Simazine
Tetrachloroethylene
1,2,4-Trichlorobenzene
Trichloroethylene
p-Xylene
Atrazine
Bromoform
1
Chlorobenzene
DBCP
p-Dichlorobenzene
trans-1,2-Dichloroethylene
1,2-Dichloropropane
EDB
Heptachlor
Hexachlorobutadiene
Pentachlorophenol
2,4,5-TP (Silvex)
Toluene
1,1,2-Trichloroethane
o-Xylene
500 gallons
Rated Service Capacity:
0.6 gpm
Rated Service Flow:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems claiming cyst reduction may be used on water containing cysts.
Manufacturer: