background image

7

Technical Support: 1-800-645-5426, Monday-Friday, 7:30 am–5:00 pm, CST

Replacement Parts

Replacement Filter Cartridges
SY-2650 

1B/2B

155832 D-250A (Cartridges sold only as a set) 

1B= White netting pre-filter 
2B= Grey post filter

3.

153126 White housing bottom

4. 151231 O-ring 

(OR-233)

5. 151242 Faucet
6.

143431 Water Supply Valve

7.

150424 Housing Wrench (SW-5)

Circuit and Probe (not shown)

For replacement parts, contact your nearest Culligan

®

water filter

retailer or call 1-888-777-7962.

4

5

6

7

3

B

1

B

2

Performance Data

WARNING: 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain filterable cysts. 

NOTE:

Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer's instructions, including replacement of filter cartridges. 

Test Conditions

Flow Rate

= as noted for filter system

Inlet Pressure

= 60 psi (4.1 bar)

pH

= 7.5±1

Temperature

= 68°F±5°F (20°C±2.5°C)

Operating Requirements

Pressure

= 30–125 psi (2.1–8.6 bar)

Temperature

= 40–100°F (4.4–37.8°C)

Turbidity

= 5 NTU Max.

Suggested Retail Price for Replacement Filter Cartridges: 

SY-2300S:

D-250A = $50.39

NOTE:

Price subject to change. Contact your local retailer or call:

1-888-777-7962 for current replacement cartridge pricing.

Содержание SY-2650

Страница 1: ...hlorine Class I and Particulate Class I Standard 53 for the reduction of MTBE Lead Mercury VOC Cyst Asbestos and Turbidity Monitored MTBE Filtration System Installation and Operating Instructions Model SY 2650 About Your CULLIGAN Monitored MTBE Filtration System Thank you for purchasing a Culligan Monitored MTBE Filtration System With only minimal maintenance your new system will provide you with ...

Страница 2: ...holes that may be used for faucet installation If these pre drilled holes cannot be used or are in an inconvenient location it will be necessary to drill a 1 2 inch hole in the sink for the faucet CAUTION Do not attempt to drill through an all porcelain sink If you have an all porcelain sink mount the faucet in pre drilled sprayer hole or drill through countertop next to sink The following instruc...

Страница 3: ... kinking and cut the tubing squarely Place a mark 5 8 inch from the end of the tubing B Wet tubing with water and insert into supply adapter 5 8 inch until mark is flush with fitting NOTE Disconnecting the Tubing from the Quick Connect Fittings Routine maintenance and cartridge replacement will not require that you disconnect the tubing from the filter system however tubing may be quickly and easi...

Страница 4: ...o ensure that the monitor works properly The monitor measures actual water usage and is powered by a single 9 volt battery How the Electronic Monitor Works The filter cartridges in the SY 2650 should be replaced every 500 gallons The electronic monitor uses a combination of lights and alarms to alert you at different stages during the life of the filter cartridges The lights are visible on the fro...

Страница 5: ...een cap and bottom of filter housing Turn off water supply valve and turn on drinking water faucet to release pressure in system Remove bottom of housing Clean O ring and O ring groove located directly beneath threads of housing Lubricate O ring with silicone grease and replace securely into groove Screw bottom of housing onto cap and hand tighten DO NOT OVER TIGHTEN Turn on water supply valve and...

Страница 6: ...le 0 0096 98 0 0002 trichloroacetonitrile 0 0015 98 0 0003 haloketones HK 1 1 dichloro 2 propanone 0 0072 99 0 0001 1 1 1 trichloro 2 propanone 0 0082 96 0 0003 heptachlor 0 0004 0 08 99 0 0004 heptachlor epoxide 0 0002 0 0107 98 0 0002 hexachlorobutadiene 0 044 98 0 001 hexachlorocyclopentadiene 0 050 0 060 99 0 000002 lindane 0 0002 0 055 99 0 00001 methoxychlor 0 040 0 050 99 0 0001 pentachloro...

Страница 7: ... unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges Test Conditions Flow Rate as noted for filter system ...

Страница 8: ...product has been designed solely for use as a housing for a disposable filter cartridge It is NOT warranted against freezing and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED WHETHER ORAL OR ARISING BY USAGE...