4. Mounting the System

(A)

Center system between water supply adapter and drinking water faucet.

NOTE:

Allow 1-1/2 inches (38 mm) clearance below system for changing filter cartridges.

(B)

Install mounting screws at least 13-3/4 inches (350 mm) from cabinet floor and 4-1/8 inches
(124 mm) apart. Leave enough space (approximately 1/2-inch [13 mm]) between the head
of the screw and the wall to slip system onto screws. 

(C)

Place system over screws on wall and slide downwards to lock into place.

CAUTION:

Make certain system is firmly attached to wall to prevent it from falling and possibly

being damaged.

5. Connecting the Faucet

CAUTION: 

Do not over-tighten compression nut. Use caution not to bend or crimp tubes when
securing. 

(A)

Determine the length of plastic tubing needed to connect the outlet (right) side of the filter
with the faucet. Measure tubing short enough to prevent kinking and cut the tubing squarely.
Screw nut of faucet stem hand tight, then unscrew two turns.

NOTE:

Compression nut should come preassembled with ferrules inside. If nut should come

apart, see figure 5A for proper assembly.

(B)

Push the tubing firmly into the end of the faucet stem. Hand-tighten compression nut onto
threads until secure. Then tighten 1-1/2 to 2 turns with wrench.

6. Connecting the Supply Adapter

(A)

Determine the length of plastic tubing needed to connect the inlet (left) side of the filter with
the supply adapter. Be sure to allow enough tubing to prevent kinking and cut the tubing
squarely. Place a mark 5/8-inch from the end of the tubing.

(B

) Wet tubing with water and insert into supply adapter 5/8-inch until mark is flush with fitting.

NOTE:

Disconnecting the Tubing from the Quick-Connect Fittings

Routine maintenance and cartridge replacement will not require that you disconnect the tubing
from the filter system; however, tubing may be quickly and easily removed from the fittings if
necessary. First, turn off the water supply to the filter. Open faucet, then press in the gray 
collar around the fitting while pulling the tubing with your other hand.

7. Connecting the System

(A)

Assemble tubing with system as shown in Fig. 7A, inserting tubing into appropriate inlet or
outlet quick-connect fitting until it stops.

NOTE:

In some installations, connecting the system to the supply adapter and/or drinking

water faucet causes the tubing to enter the quick-connect fitting at a sharp angle. This may
exert pressure on the quick-connect fitting and cause it to leak. In these situations, you may
wish to use one or both of the quick-connect elbows included with the installation kit. Simply
push the quick-connect elbow directly into the quick-connect fitting on the system, then insert
the tubing into the quick-connect elbow.

(B)

When cut between a set of black guide arrows, the tubing should be pushed into the fitting so
that the entrance of the fitting falls between the next set of guide arrows (approximately 5/8
inch [16 mm]). 

3

Technical Support: 1-800-645-5426, Monday-Friday, 7:30 am–5:00 pm, CST

5

B

A

4

A

B

C

1-1/2"
38 mm

13-3/4"
350 mm

6

A

B

A

4-1/8"

105 mm

5/8"

16 mm

5/8"

16 mm

7

A

B

5/8"

16 mm

Содержание SY-2650

Страница 1: ...hlorine Class I and Particulate Class I Standard 53 for the reduction of MTBE Lead Mercury VOC Cyst Asbestos and Turbidity Monitored MTBE Filtration System Installation and Operating Instructions Model SY 2650 About Your CULLIGAN Monitored MTBE Filtration System Thank you for purchasing a Culligan Monitored MTBE Filtration System With only minimal maintenance your new system will provide you with ...

Страница 2: ...holes that may be used for faucet installation If these pre drilled holes cannot be used or are in an inconvenient location it will be necessary to drill a 1 2 inch hole in the sink for the faucet CAUTION Do not attempt to drill through an all porcelain sink If you have an all porcelain sink mount the faucet in pre drilled sprayer hole or drill through countertop next to sink The following instruc...

Страница 3: ... kinking and cut the tubing squarely Place a mark 5 8 inch from the end of the tubing B Wet tubing with water and insert into supply adapter 5 8 inch until mark is flush with fitting NOTE Disconnecting the Tubing from the Quick Connect Fittings Routine maintenance and cartridge replacement will not require that you disconnect the tubing from the filter system however tubing may be quickly and easi...

Страница 4: ...o ensure that the monitor works properly The monitor measures actual water usage and is powered by a single 9 volt battery How the Electronic Monitor Works The filter cartridges in the SY 2650 should be replaced every 500 gallons The electronic monitor uses a combination of lights and alarms to alert you at different stages during the life of the filter cartridges The lights are visible on the fro...

Страница 5: ...een cap and bottom of filter housing Turn off water supply valve and turn on drinking water faucet to release pressure in system Remove bottom of housing Clean O ring and O ring groove located directly beneath threads of housing Lubricate O ring with silicone grease and replace securely into groove Screw bottom of housing onto cap and hand tighten DO NOT OVER TIGHTEN Turn on water supply valve and...

Страница 6: ...le 0 0096 98 0 0002 trichloroacetonitrile 0 0015 98 0 0003 haloketones HK 1 1 dichloro 2 propanone 0 0072 99 0 0001 1 1 1 trichloro 2 propanone 0 0082 96 0 0003 heptachlor 0 0004 0 08 99 0 0004 heptachlor epoxide 0 0002 0 0107 98 0 0002 hexachlorobutadiene 0 044 98 0 001 hexachlorocyclopentadiene 0 050 0 060 99 0 000002 lindane 0 0002 0 055 99 0 00001 methoxychlor 0 040 0 050 99 0 0001 pentachloro...

Страница 7: ... unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges Test Conditions Flow Rate as noted for filter system ...

Страница 8: ...product has been designed solely for use as a housing for a disposable filter cartridge It is NOT warranted against freezing and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED WHETHER ORAL OR ARISING BY USAGE...

Отзывы: